Monomax PC 550
One Piece hydrophilic acrylic IOL with 2 Mod. C loops (Acrysof -like).
Showing 197–224 of 325 results
One Piece hydrophilic acrylic IOL with 2 Mod. C loops (Acrysof -like).
The NuLens Dynacurve accommodative IOL (NuLens, Ltd., Herzliya Pituah, Israel) consists of: 1) polymethyl methacrylate (PMMA) haptics that are designed to be placed in the ciliary sulcus; 2) a PMMA anterior reference plane that provides distance vision correction; 3) a small chamber containing a solid silicone gel and 4) a posterior piston with an aperture in the center.
Such IOL prototypes, even with silicone gel of a relatively low refractive index (1.40), have been shown in a primate eye to deliver more than 40.00 D of accommodation using only 500 µm of vertical diaphragm displacement. No wonder the principle was evaluated clinically in AMD Patients, providing additional evidence regarding the Concept of possible extreme Accommodation. This Prototype of lens required a 9mm incision to be inserted in the sulcus/bag.
Hydrophilic IOL one Piece from VSY.
Hydrophobic Acrylic containing Natural Chromophore Trifocal Aspheric IOL with nominal light distribution 45% distance, 27% intermediate (+1.85D) and 28% near (+3.50D)
Hydrophobic acrylic material natural yellow tinted (resembling a natural 40 yo crystalline lens -as per it’s Germany-Heidelberg located manufacturer ). Also available in a fully preloaded Version.
Requires fair incision of >7.0mm. Pupillary Aperture 3.5mm. Not for sclera fixation
larger then 67. 67A total Diameter 14.0mm. Intended for myopic eyes. Requires fair incision of >7.0mm. Pupillary Aperture 3.5mm. Not for sclera fixation
total Diameter 13.5 mm. Requires fair incision of >7.0 mm. Pupillary Aperture 3.5 mm. With positioning holes for intrasleral fixation through sutures (9-0 Prolene on Spatula needle)
total IOL Diame ter 13.5 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation. (9-0 Prolene-spatula Needle)
total IOL Diameter 13.5 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 5.0 mm. Not for sclera fixation through sutures!
total IOL Diameter 14.00 mm. Requires fair incision of >7.0 mm. Pupillary Aperture 3.5 mm. Two positioning holes in each haptic for suture to sclera fixation.
total Diameter 13.5 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0 mm. Not for sclera fixation through sutures!
total IOL Diame ter 13.5.00 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation.
All the Available PMMA Models from Alcon for Use in the Anterior Chamber. All require large incisions (5.7mm). MUST Follow Sizing Guidance ! 6 Models Available ….
For detailed description visit the site
https://www.myalconstore.com/education-resources/surgical-product-information/
Six Old Fashioned PMMA IOLs Models from Alcon requiring large incisions. For Reference and special cases only.
This is a multicomponent Lens system with two Optics, one of which can be easily exchanged, may work for pediatric cases and cases anticipated to have ametropia postop. Online calculator . French CE marked technology.
Posterior Optical Plate Aspheric Hydrophobic, Anterior Plate is Hydrophilic with Spherical Optic, Both are 5.7mm diameter. Both can be made clear or yellow colored.
One Piece hydrophilic acrylic IOL available in wide dioptic range.
One Piece IOL from “Hybrid” Acrylic Material and “Hydrid” Optics (3 refractive rings), marketed as Continuous Transition Focus with SA 0 or SA -0,11μ.
One Piece hydrophilic acrylic IOL with toricity.
One Piece hydrophilic acrylic IOL with 4 closed loops.
ADD ON Hydrophilic Acrylic IOL for for < 2.20mm incision Surgery, with spherical Optics, Ventilating holes, from France and IOLART (GR/CY)
S
Hydrophilic IOL one Piece from Care Group This model with aspheric Optics and Blue light protection.
The Sapphire IOL (Elenza) is electronically controlled, remotely programmable, customisable and utilises nanotechnology, artificial intelligence and advanced electronics to auto-adjust focus in response to pupillary changes. Speed and amplitude of pupillary responses are used to differentiate between light and accommodation. The power-cell requires recharging every three-to-four days, has hibernation mode and a fail-safe mechanism that converts it to monofocal status till recharged.
First announced in 2011, Many Prominent Ophthalmic Surgeons in the directory Board of Elenza, One of the two probable current “electronic IOL” .
Peculiar looking suturefree IOL for Fixation under scleral flaps throygh Trascleral plugs. Customized optic to provide toricity control at 0,25D steps! Injector: Medical Viscojet 2.2 or 2.7 . As per Company 2 week delivery time.
Watch the video!