No

Showing 29–56 of 325 results

AcrySof IQ Toric SN6ATT

one piece hydrophobic Acrylic monofocal IOL with aspheric optics and Astigmatism cotrol from 1D to 6D (IOL Plane)

AcrySof MA60 MA/ MN60 MA

White (MA) or Yellow spherical Optic, 3-piece IOL for LOW POWERS (-5.0D to +5.0D)only.  Also for Alternative Fixation Sulcus/Sclera/ Iris

AcrySof SA60 AT/ SN60 AT

White (MA) or Yellow spherical (SN) with aspheric Optic One piece Hydrophobic IOL, extended dioptric Range to +40.0 D.

Akreos AO60 (Bausch + Lomb)

Specialized Lens for MICS incisions less then 2.2 mm. Available in 10,5mm (for hyperopic) 10,7mm (Emmetropic) & 11.00mm (Myopic Eyes) sizes according to corresponding Power of the IOL.  Low index of refraction is supposed to limit Reflections from the IOL.. (As Adapt the Optic is Spheric- as AO it is  aspheric)

Akreos MICS M160L IOL (Bausch + Lomb)

Specialized Lens for MICS incisions less then 2.2 mm. Available in 10,5mm (for hyperopic) 10,7mm (Emmetropic) & 11.00mm (Myopic Eyes) sizes according to corresponding Power of the IOL.  Optic Zone is from 6,2mm in low Powered Lenses to 5.6mm in high powered Lenses  ( >22.0 D!)  Low index of refraction is supposed to limit Reflections from the IOL.

Alsafit Fourier Trifocal (Alsanza)

total presbyopia correcting, one piece IOL (TRIFOCAL IOL) with alleged impressive light transmission 91.4%.

material: smart matrix, interpenetrating polymer network of hydrophobic and hydrophilic acrylic

haptic design features : 4 suspensive corner fins, 2 wide OVD aspiration holes, 4 positioning holes

Addition: +3.55D at 35cm , +1.77 D at 70cm

Company claims their design with  “Fourier” Designed “reverse Apodization” will improve 24h light distribution and Dysphotopic symptoms. -Height of harmonic waves (no diffractive steps) INCREASE from center to periphery!

Aniridia Implant Type 67G Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 5.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle. Also without Optic Available.

NB Intraop support of the IOL with Long Prolene Needle (Dr Sundmacher et al) https://www.youtube.com/watch?v=ucrk-EVDdMU

Aniridia Implant Type 67L Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 3.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle Opening in the diaphragm inferiorly for the injection of Vitreous Fluid Substitutes/ inferior iridotomy for silicone oil.

Aniridia Implant Type 68 Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 4.5 mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle

Aniridia Implant Type 94A Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 6.5 mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle. Only without Optic Available. Sulcus with/without Sclera fixation. (For Existing Pseudophakia)