311 Aniridia Implant (Ophtec)
https://www.youtube.com/watch?time_continue=29&v=KJ-7u2QWqw4
IOL-Iris Composite device with 4mm optic. Requires a big wound, We do not advice utilizing anything but black!
Showing all 25 results
https://www.youtube.com/watch?time_continue=29&v=KJ-7u2QWqw4
IOL-Iris Composite device with 4mm optic. Requires a big wound, We do not advice utilizing anything but black!
Foldable Iris Fixated IOL designed for spherical and cylindrical correction for moderate and high myopic eyes
Iris fixated IOL designed for a spherical correction in cases of inefficient capsular Support.
In our opinion it is primarily a posterior Chamber Lens (A*=116.8) that may be enclavated in the Anterior Chamber if needed (A*=115,7) Note that the aphakic and less expensive Version is Biconvex (Only +2D to +9.0 are plano-Convex)
*Optical
PMMA Iris Fixated IOL for correction of Hyperopia.
NB: we no longer recommend the use of this lens in phakic eyes
Customized Solution to bridge Iris Defect and correct aphakia at the same time. Needs 6-8 weeks order time.
Iris fixated PMMA IOL for myopia correction in Phakic Eyes. A preferred choice for most patients.
Iris fixated IOL designed for a spherical and cylindrical correction of myopic and hyperopic eyes.
N.B. The site does NOT recommend the use of this lens in Hyperopic Phakic Eyes.
1% NaHA with >5 million Daltons Molecular Weight and high Viscosity: 1 million cPs Zero shear rate, in 0,55ml and 0,85ml syringe. 27G cannula.
1,4% NaHA with >5 million Daltons Molecular Weight and high Viscosity: 3.3 million cPs Zero shear rate, in 0,55ml and 0,85ml syringe. 25G cannula.
the IPS is a PMMA prosthesis for an intact capsular bag. A total pupillary reconstruction requires 2 segments, Use with a CTR.
One Piece hydrophilic acrylic IOL with 2 Mod. C loops (Acrysof -like).
1% NaHA with 1.0Million Daltons Molecular Weight and high Viscosity: 1 million cPs Zero shear rate, in 0,55ml and 0,85ml syringe. 27G cannula.
classic 2%HPMC provided in 2ml Syringe (23G/25G Canula)
non Glistening Hydrophobic material (Originally from MBI) with superb clarity/ optical performance. One Piece Lens with modified two open loops.
One Piece hydrophilic acrylic IOL available in wide dioptic range.
One Piece IOL from “Hybrid” Acrylic Material and “Hydrid” Optics (3 refractive rings), marketed as Continuous Transition Focus with SA 0 or SA -0,11μ.
One Piece hydrophilic acrylic IOL with toricity.
Typical 2.0% HPMC, in a 2.0 ml Syringe and 23G Cannula. Low Viscosity with maximal Coating Effect Dispersive, -23g Cannula
One Piece hydrophilic acrylic IOL with 4 closed loops.
The Robomarker is a self levering Corneal Marker with integrated fixation light and an Axis-Adjustable Marking Tip. Currently Marketed from Ophtec
The Company will continue to compute IOL power in the phakic situation from Refraction and AC Depth to estimate the Effective Lens Positioning for every IOL ordered. In Greece and Cyprus through Systemvision.
Iris fixated IOL designed for use in phakic Eyes. In our opinion the 5.00 OZ is more versatile and preferred in myopia without significant astigmatism.