Rayner

Showing all 24 results

M-flex 580F/ 630F (Rayner)

Bifocal Lens adding +3.0 OR +4.0 at IOL plane, with 5,75mm (580F) or 6.25mm (630F) optical Zone.  +3.00 Add offered from +14.0D to 30.0D Range (0,5D increments) and +4.00 Add offered from +10.0 D to +30.0D

M-flex T 588F/ 638F (Rayner)

Bifocal Lens adding +3.0 OR +4.0 at IOL plane, with 5,75mm (580F) or 6.25mm (630F) optical Zone.  +3.00 Add offered from +14.0D to 30.0D Range (0,5D increments) and +4.00 Add offered from +10.0 D to +30.0D

MethylVisc 2.0% (OVD) Rayner

Typical  2.0% HPMC, in a 2.0 ml Syringe and 23G Cannula. Low Viscosity with maximal Coating Effect 2600-7.00mPa / Dispersive

Ophteis (OVD) Rayner

Animal Origin, 1% NaHA, High molecular Weight (5mill) resulting in high Viscosity and Pseudoplasticity resulting in good space creation and controlled IOL injection and facilitating easy removal at the end of Surgery

Ophteis + (OVD) Rayner

Animal Origin, 1,4% NaHA, High molecular Weight (5mill) resulting in high Viscosity and Pseudoplasticity resulting in good space creation and controlled IOL injection and facilitating easy removal at the end of Surgery

Ophteis BIO 1,6% (OVD) Rayner

Obtained by Biofermentation NOT Anmal Origin, 1,6% NaHA, High molecular Weight -Dalton (3mill) resulting in quite high Viscosity and Pseudoplasticity resulting in good space creation and controlled IOL injection and facilitating easy removal at the end of Surgery. 1,1 ml Syringe Volume , 27 G Cannula!

Classified by Company as Cohesive

Ophteis BIO 1,8% (OVD) Rayner

Obtained by Biofermentation NOT Anmal Origin, 1,8% NaHA, High molecular Weight -Dalton (3mill) resulting in good cohesivity at low shear-rates (Zero Shear Viscosity ~600.000 mPas- but also strong coating ability (improved dispersive Properties) Easy removal at the end of Surgery. 1,1 ml Syringe Volume , 27 G Cannula!

Classified by Company as Cohesive

Ophteis BIO 3% (OVD) Rayner

Obtained by Biofermentation NOT Anmal Origin, 3.0% NaHA, Molecular Weight -Dalton (0,75mill) resulting in best possible Coating Ability (and Endothelium Protection) even at high shear-rates (Zero Shear Viscosity only ~30.000 mPas- but also strong coating ability (improved dispersive Properties) Easy removal at the end of Surgery. 1,1 ml Syringe Volume , 25 G Cannula!

Classified by Company as Dispersive

OphteisMax B-OPX085 (OVD) Rayner

Animal Origin, 2,5% NaHA, High molecular Weight -Dalton (4mill) resulting in high Viscosity and Pseudoplasticity resulting in good space creation and controlled IOL injection and facilitating easy removal at the end of Surgery. 0,85ml Syringe Volume , 25 G Cannula!

Classified by Company as Visco-Adaptive (under Stress it behaves like dispersive)

P-Flex IOL Investigational (Rayner)

Investigational Device from Rayner with deflecting Fresnel Optics to deflect light away from scotoma onto healthy Retina. Ordinary IOL for in the bag placement

RayOne Aspheric IOL RAO600C (Rayner)

Preloaded Hydrophilic (Rayacryl-26% H2O)  IOL with Anterior Aberration Neutral Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).

RayOne Trifocal IOL RAO603F (Rayner)

Preloaded Hydrophilic (Rayacryl-26% H2O)  IOL with Anterior Aberration Neutral Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).

Sulcoflex Aspheric IOL 700L (Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia in pseudophakia. The IOL is supplied with a Rayner Injector.

Sulcoflex Multifocal IOL 653F(Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision).  Add +3,5D at IOL plane.

Sulcoflex Multifocal Toric IOL 653F (Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Bifocal Add +3,5D at IOL plane.

Sulcoflex Toric IOL 710LT (Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia (Sphere and astigmatism) in pseudophakia. The IOL is supplied with a Rayner Injector for incisions <2.7mm.

Sulcoflex Trifocal IOL 703F (Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Trfocal Add +1.75D and 3,5D at IOL plane.