FIL 613 IOL Prime (Soleko)
Hydrophilic monofocal one Piece IOL with aspheric Optics 6/13 optic-overall length
Showing 113–140 of 325 results
Hydrophilic monofocal one Piece IOL with aspheric Optics 6/13 optic-overall length
one piece hydrophilic IOL where the Optical Element is connected to the Supporting Annulus through a Helix to theoretically allowe pivoting of the optic.
one piece hydrophilic IOL with Soleco’s 4 small diameter refractive central zone (trifocal) , designed for kids/ bag/ sulcus and sclera fixation.
preloaded Hydrophobic Acrylic IOL for in the bag placement
preloaded Hydrophobic Acrylic IOL for in the bag placement
preloaded Hydrophobic Acrylic IOL for in the bag placement
The FluidVision® Accommodating Intraocular Lens
Accommodation refers to the eye’s ability to dynamically adjust focus for clear vision at all distances. The FluidVision accommodating IOL from PowerVision contains a tiny amount of fluid inside the lens that moves in response to the natural muscle forces in the eye. The FluidVision lens provides True Accommodation™ by mimicking the eye’s natural accommodative process, changing shape and becoming thicker when the patient needs to see up close or thinner to see far away. (from Powervision Website)
Unlike the Nulens and the Lumina this 3rd investigational Device meant to change the Curvature in vivo is meant to be placed in the capsule.
This Device is designed to protect the Crystalline Space for current and future applications. Replacing the 260mg cataract with our current 15mg implant technology might not be the right solution for the future. It may even survive the era of Refractive Indexing. (Possible applications with Augmented Reality/ Zooming and Drug delivery Reservoir.
By ClarVistamedical -aquired by Alcon- comes a multicomponent IOL from Hydrophobic acrylic that the optic is adapted to the blue rim in situ. CE Marked.
Harmonis Top of the line individually Customized IOL, customizing % of Light intensity to Far Vision (40-80%), Intermiediate Vision (10-30%) and near Vision (10-48%). Proprietary EDOF technology that excibits a unique exagerrated aspheric (central region 1mm- Instant Focus Technology) combined with a diffractive Annulus to 3,7mm, monofocal (prob Aspheric) Refractive (to 6mm) properties. One piece Hydrophilic acrylic with double closed loops IOL in two Sizes.
one piece hydrophobic IOL with 4 point fixation -4 closed loops.
one piece hydrophobic IOL with 4 point fixation -4 closed loops -Preloaded .
one piece hydrophobic IOL with traditional design.
3-piece IOL with Hydrophobic Glistening Free and Spheric Optics (+0,2μ)
bifocal l IOL from Germany (i-Medical Heidelberg) with diffractive +3.00 OR +3.5D OR +4.00 near, in Hydrophilic, Plate -p model or modified closed C-loops -r model-
trifocal IOL from Germany (i-Medical Heidelberg) with diffractive +1,8D intermediate and +3.5D near, in Hydrophilic, Plate Configuration.
Gallilean Type of Micro-Telescope implanted also with inserter through a small corneosclera incision of 3mm (Tsert CI -Inserter- 2nd Image)
www.visioncareinc.net
InFO for Instant Focus: Proprietary EDOF technology that excibits a unique exagerrated aspheric (central region), combined with refractive diffractive properties. One piece Hydrophilic acrylic with double closed loops IOL in two Sizes.
The Principle of the Accufocus intracorneal Implant -Kamra- realized in standard IOL technology
May be also appropriate for use in cases with corneal related macro aberrations
The “pinhole principle” is meant to increase depth of focus to about 3D. It has a non-diffractive 3.23mm diameter opaque PVDF mask with 1.36mm central aperture.
(NB Discuss possibility of Pulfrich Effect because of Dissimilar Intensity of Light between lights -consider dilating one eye only during consultation)
The IOL K features a centrally located high negative powered portion (1.7mm) covering the central scotoma but not interfearing with the rest of the optical Zone thus -according to the company- not affecting the patients mobility so much. With High powered Positive Specs the Patients enjoys a mag to 3x from the combination of the negative powered central portion of the IOL and the Hyperopic Specs (Gallilean Telescope)
Gallilean Type of Telescope: This Old-fashioned approach offers magnification through combination of a large + lens (up to +100D) placed in the bag and a strong meniscus minus AC Implant. Made from Lenspecial -Milano, Italy. (PMMA) System has an incredible 200D dioptic Range (+100D to -100D)
Gallilean Type of Telescope: This Old-fashioned approach offers magnification through combination of a large + lens (up to +100D) placed in the bag and a strong meniscus minus AC Implant. Made from Lenspecial -Milano, Italy. (PMMA)
Gallilean Type of Telescope: Combines a PMMA Rim with a double lens system. The PMMA Ring has 10.3mm diameter
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
on line Calculator http:/www.ipciol.com/calc