Artis Y PL (Cristalens)
yellow tinted hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)
Showing 57–84 of 306 results
yellow tinted hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)
Iris fixated IOL designed for a spherical correction in cases of inefficient capsular Support.
In our opinion it is primarily a posterior Chamber Lens (A*=116.8) that may be enclavated in the Anterior Chamber if needed (A*=115,7) Note that the aphakic and less expensive Version is Biconvex (Only +2D to +9.0 are plano-Convex)
*Optical
Hydrophobic IOL one Piece from Care Group This model with Aberration Free ,360 Square edge aspheric Optics.
Hydrophilic -Biconvex yellow tinted with open modified C-loop haptic configuration. Diffractive aspheric optics adding +3.25D (IOL plane) 360 Square edge Optics.
Hydrophilic -Biconvex yellow tinted with open modified C-loop haptic configuration. Diffractive aspheric optics adding +3.25D (IOL plane) 360 Square edge Optics.
“iDIFF Plus is a newer generation refractive-diffractive presbyopic IOL with an increasing step height diffractive pattern combined with increased step angulation between transition zones, resulting in superior optical quality for both distance and near. The design enables balanced distribution of light (60/40 light distribution for far and near respectively) and higher MTF values, which increases contrast sensitivity in all lighting conditions and reduces the effects of scattered light, such as persistent glare and haloes and is pupil independent.” copied from website.
Comes as iDiff R (C-loop haptics) and iDiff P (plate) in 3 Adds +4.00/ +3.50/ +3.00
Hydrophobic yellow tinted with open modified C-loop haptic configuration IOL that corrects Astigmatism -1-6 dpt . (IOL plane) 360 Square edge Optics. 0,5 Increment step
Hydrophobic -Yellow-preloaded one Piece IOL from Care Group This model with negative aspheric ,360 Square edge Optics.
Hydrophobic -Yellow- IOL one Piece from Care Group This model with Aberration Free ,360 Square edge aspheric Optics.
3- piece hydrophilic Acrylic lens with C-loop Highly Flexible Haptics, aspherical Optics and refractive technology. For capsular bag fixation.
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive technology. For capsular bag fixation. Infinite Spherical Correctiuon -20D to +60D …aAY: with yellow Chromophore
One piece hydrophilic Acrylic plate lens with 4closed loop Haptics. Aspherical Optics and 6.0 mm optical Zone. For capsular bag fixation.
One piece hydrophilic Acrylic plate lens with 4closed loop Haptics. Aspherical Optics and 6.0 mm optical Zone. For capsular bag fixation.
One piece plate hydrophilic Acrylic lens with aspherical Optics and very large 7mm Optic for capsular bag fixation
Preloaded hydrophobic one piece Acrylic IOL with modified C-loop Configuration. from Kowa-Japan. This Version is clear, not yellow.
Preloaded hydrophobic one piece Acrylic IOL with modified C-loop Configuration. from Kowa-Japan
one piece Hydrophilic acrylic with 4 haptic fixation and astigmatism control T3 (1,5 D -IOL Plane) to T9 (6.0D IOL Plane) -7 models
online Calculator www.omnitoric.in
Online program to chose between 7 models controlling astigmatism from 1-4D (Spectacle Plane)
T3 (1,5 D -IOL Plane) to T9 (6.0D IOL Plane)
online Calculator www.omnitoric.in
Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophilic Acrylic Lens from Israel.
Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophobic Acrylic Lens from Israel.
Anterior Aspheric SA=0 5,75mm Optic in a 12.0 Hydrophilic Acrylic Lesn for in the Bag Fixation.
Spheric 5,75mm Optic in a 12.0 Hydrophilic Acrylic
one piece hydrophilic IOL designed for in the bag/ alternative fixation (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for in the bag/ alternative fixation (Named after the two bumps on each haptic)
Toric model with Real Axis Technology (1-6 Dpt, Place IOL always 0-180, Astigmatism is custome-made with 1degree accuracy,
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
Hydrophilic Acrylic for < 2.20mm incision Surgery, with Spherical Surface f, extended Range in myopia, from France and IOLART (GR/CY)
one piece hydrophobic Acrylic monofocal IOL with aspheric optics, Preloaded with brilliant Single Use, C02 Propulsion System. Glistening Free.