Partial Aniridia Implant Type 67E Morcher
total IOL Diame ter 13.5 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation. (9-0 Prolene-spatula Needle)
Showing 197–224 of 306 results
total IOL Diame ter 13.5 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation. (9-0 Prolene-spatula Needle)
total IOL Diameter 13.5 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 5.0 mm. Not for sclera fixation through sutures!
total IOL Diameter 14.00 mm. Requires fair incision of >7.0 mm. Pupillary Aperture 3.5 mm. Two positioning holes in each haptic for suture to sclera fixation.
total Diameter 13.5 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0 mm. Not for sclera fixation through sutures!
total IOL Diame ter 13.5.00 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation.
All the Available PMMA Models from Alcon for Use in the Anterior Chamber. All require large incisions (5.7mm). MUST Follow Sizing Guidance ! 6 Models Available ….
For detailed description visit the site
https://www.myalconstore.com/education-resources/surgical-product-information/
Six Old Fashioned PMMA IOLs Models from Alcon requiring large incisions. For Reference and special cases only.
non Glistening Hydrophobic material (Originally from MBI) with superb clarity/ optical performance. One Piece Lens with modified two open loops.
non Glistening Hydrophobic material (Originally from MBI) with superb clarity/ optical performance. One Piece Lens with modified two open loops.
One Piece hydrophilic acrylic IOL available in wide dioptic range.
One Piece IOL from “Hybrid” Acrylic Material and “Hydrid” Optics (3 refractive rings), marketed as Continuous Transition Focus with SA 0 or SA -0,11μ.
One Piece hydrophilic acrylic IOL with toricity.
preloaded Hydrophobic Acrylic IOL for in the bag placement
One Piece hydrophilic acrylic IOL with 4 closed loops.
Preloaded Hydrophilic (Rayacryl-26% H2O) IOL with Anterior Aberration Neutral Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).
Preloaded Hydrophilic (Rayacryl-26% H2O) IOL with Spherical Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).
Preloaded Hydrophilic (Rayacryl-26% H2O) IOL with Spherical Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).
Preloaded Hydrophilic (Rayacryl-26% H2O) IOL with Anterior Aberration Neutral Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).
Hydrophilic IOL one Piece from Care Group This model with aspheric Optics and Blue light protection.
Peculiar looking suturefree IOL for Fixation under scleral flaps throygh Trascleral plugs. Customized optic to provide toricity control at 0,25D steps! Injector: Medical Viscojet 2.2 or 2.7 . As per Company 2 week delivery time.
Watch the video!
Peculiar looking suturefree IOL for Fixation 23G.
Watch the video!
Designed on Zemax for optimized MDF performance this is a conventional c loop aspheric one piece Hydrophilic Acrylic Lens from Israel.
Designed on Zemax for optimized MDF performance this is a conventional c loop aspheric one piece Hydrophobic Acrylic Lens from Israel.
monofocal, Hydrophobic Acrylic IOL, not Preloaded
monofocal, 3-pieceACRYLIC IOL (13mm) with Aspheric correcting Optics and OptiEdge Design.
the ME Model has an overall diameter 13.5mm