Akreos AO60 (Bausch + Lomb)
Specialized Lens for MICS incisions less then 2.2 mm. Available in 10,5mm (for hyperopic) 10,7mm (Emmetropic) & 11.00mm (Myopic Eyes) sizes according to corresponding Power of the IOL. Low index of refraction is supposed to limit Reflections from the IOL.. (As Adapt the Optic is Spheric- as AO it is aspheric)
Akreos MICS M160L IOL (Bausch + Lomb)
Specialized Lens for MICS incisions less then 2.2 mm. Available in 10,5mm (for hyperopic) 10,7mm (Emmetropic) & 11.00mm (Myopic Eyes) sizes according to corresponding Power of the IOL. Optic Zone is from 6,2mm in low Powered Lenses to 5.6mm in high powered Lenses ( >22.0 D!) Low index of refraction is supposed to limit Reflections from the IOL.
alfa Iris Clip Lens (CareGroup)
Iris fixated IOL from India. From the Care Group.
Alsafit Fourier Trifocal (Alsanza)
total presbyopia correcting, one piece IOL (TRIFOCAL IOL) with alleged impressive light transmission 91.4%.
material: smart matrix, interpenetrating polymer network of hydrophobic and hydrophilic acrylic
haptic design features : 4 suspensive corner fins, 2 wide OVD aspiration holes, 4 positioning holes
Addition: +3.55D at 35cm , +1.77 D at 70cm
Company claims their design with “Fourier” Designed “reverse Apodization” will improve 24h light distribution and Dysphotopic symptoms. -Height of harmonic waves (no diffractive steps) INCREASE from center to periphery!
Aniridia Implant Type 67B Morcher
Requires huge incision of >10.0mm. Pupillary Aperture 3.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle
Aniridia Implant Type 67G Morcher
Requires huge incision of >10.0mm. Pupillary Aperture 5.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle. Also without Optic Available.
NB Intraop support of the IOL with Long Prolene Needle (Dr Sundmacher et al) https://www.youtube.com/watch?v=ucrk-EVDdMU
Aniridia Implant Type 67L Morcher
Requires huge incision of >10.0mm. Pupillary Aperture 3.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle Opening in the diaphragm inferiorly for the injection of Vitreous Fluid Substitutes/ inferior iridotomy for silicone oil.
Aniridia Implant Type 68 Morcher
Requires huge incision of >10.0mm. Pupillary Aperture 4.5 mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle
ANKORIS toric / PhysIOL
preloaded Hydrophobic Acrylic IOL for in the bag placement
ANU6 AS Ocuflex Monofocal Aspheric IOL
Hydrophilic IOL one Piece from Care Group This model with aspheric Optics.
ANU6 Ocuflex Monofocal Spheric IOL
Hydrophilic IOL one Piece from Care Group This model with Spheric Optics.
Aquafold CBF32/ CBF82 UVA(Omni Lens)
one piece Hydrophilic acrylic with modified C loops and spheric Optic. Extended Range -5.0D to +7.0 D available on request.
Aquafold Flex CBF32 UV FL / CBF81 UV FL (Omni Lens)
one piece Hydrophilic acrylic with modified C loops and spheric Optic. Extended Range -5.0D to +7.0 D available on request.
Aquafold Quadra PBF37 UVQ (Omni Lens)
one piece Hydrophilic acrylic with 4 haptic fixation. Extended Range -5.0D to +7.0 D available on request.
Artis PL E (Cristalens)
hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)
ARTIS PL M (Cristalens)
Preloaded Hydrophobic Acrylic Bifocal IOL for for < 2.20mm incision Surgery, with Aspherical posterior Surface (Aberration Compensating) with near Add +3.00D (standard) or +2.50 (on request) , from France and IOLART (GR/CY)
ARTIS T PL E (Cristalens)
Hydrophobic Acrylic Toric IOL for for < 2.20mm incision Surgery, with Aspherical posterior Surface (Aberration Neutral), from France and IOLART (GR/CY)