FIL 611 IOL Prime (Soleko)
4-point support Hydrophilic monofocal one Piece IOL with aspheric Optics 6/11 optic-overall length
Showing 113–140 of 314 results
4-point support Hydrophilic monofocal one Piece IOL with aspheric Optics 6/11 optic-overall length
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Toric Customized Hydrophylic one Piece IOL. Axis of IOL to implanted always at 0-180.
Toric Customized Hydrophylic Multifocal Lens (customized sphere/ astigmatism) 0,25D steps. 4 concentric refractive rings!
Hydrophilic monofocal one Piece IOL with aspheric Optics for in the bag/ sulcus and sclera fixation through sutures
Hydrophilic monofocal one Piece IOL with aspheric Optics 6/13 optic-overall length
one piece hydrophilic IOL where the Optical Element is connected to the Supporting Annulus through a Helix to theoretically allowe pivoting of the optic.
one piece hydrophilic IOL with Soleco’s 4 small diameter refractive central zone (trifocal) , designed for kids/ bag/ sulcus and sclera fixation.
one piece hydrophobic IOL with 4 point fixation -4 closed loops.
one piece hydrophobic IOL with 4 point fixation -4 closed loops -Preloaded .
one piece hydrophobic IOL with traditional design.
bifocal l IOL from Germany (i-Medical Heidelberg) with diffractive +3.00 OR +3.5D OR +4.00 near, in Hydrophilic, Plate -p model or modified closed C-loops -r model-
trifocal IOL from Germany (i-Medical Heidelberg) with diffractive +1,8D intermediate and +3.5D near, in Hydrophilic, Plate Configuration.
Gallilean Type of Micro-Telescope implanted also with inserter through a small corneosclera incision of 3mm (Tsert CI -Inserter- 2nd Image)
www.visioncareinc.net
The Principle of the Accufocus intracorneal Implant -Kamra- realized in standard IOL technology
May be also appropriate for use in cases with corneal related macro aberrations
The “pinhole principle” is meant to increase depth of focus to about 3D. It has a non-diffractive 3.23mm diameter opaque PVDF mask with 1.36mm central aperture.
(NB Discuss possibility of Pulfrich Effect because of Dissimilar Intensity of Light between lights -consider dilating one eye only during consultation)
The IOL K features a centrally located high negative powered portion (1.7mm) covering the central scotoma but not interfearing with the rest of the optical Zone thus -according to the company- not affecting the patients mobility so much. With High powered Positive Specs the Patients enjoys a mag to 3x from the combination of the negative powered central portion of the IOL and the Hyperopic Specs (Gallilean Telescope)
Gallilean Type of Telescope: This Old-fashioned approach offers magnification through combination of a large + lens (up to +100D) placed in the bag and a strong meniscus minus AC Implant. Made from Lenspecial -Milano, Italy. (PMMA) System has an incredible 200D dioptic Range (+100D to -100D)
Gallilean Type of Telescope: This Old-fashioned approach offers magnification through combination of a large + lens (up to +100D) placed in the bag and a strong meniscus minus AC Implant. Made from Lenspecial -Milano, Italy. (PMMA)
Gallilean Type of Telescope: Combines a PMMA Rim with a double lens system. The PMMA Ring has 10.3mm diameter
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D”
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D” and astigmatism up to +10.0 D.
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
on line Calculator http:/www.ipciol.com/calc