same as optic

Showing 85–112 of 314 results

BunnyLens AF (Hanita Lenses)

Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophilic Acrylic Lens from Israel.

BunnyLens HP (Hanita Lenses)

Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophobic  Acrylic Lens from Israel.

Camellens FIL 622-1 T IOL (Soleko)

one piece hydrophilic  IOL designed for in the bag/ alternative fixation (Named after the two bumps on each haptic)

Toric model with Real Axis Technology (1-6 Dpt, Place IOL always 0-180, Astigmatism is custome-made with 1degree accuracy,

CB144 UV2 PMMA IOL (Omni Lens)

one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation

CB144 UV2 PMMA IOL (Omni Lens)

one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation

CLARE (Cristalens)

Hydrophilic Acrylic for < 2.20mm incision Surgery, with  Spherical Surface  f, extended Range in myopia, from France and IOLART (GR/CY)

Clareon AutonoMe CNA0T0 -Alcon

one piece hydrophobic Acrylic monofocal IOL with aspheric optics, Preloaded with brilliant Single Use, C02 Propulsion System. Glistening Free.

CRISTAL (Cristalens)

Hydrophilic Acrylic for < 2.20mm incision Surgery, with  Aspherical posterior  Surface (Aberration Neutral), from France and IOLART (GR/CY)

Diffractiva-aA/ aA Yellow HumanOptics

One piece  hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive/diffractive technology offering +3.50D Add (IOL Plane). For capsular bag fixation. DOLA Technology: Diffractive Optic Local Asphericity –DOLA– meant to reduce Halo/ Dysphotopic Burden of Bifocal IOLs.

EAZ-Y (Cristalens)

yellow tinted hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)

EVOLVE EDOF Customized Toric Hydrophilic (Soleko)

one piece hydrophilic  IOL with EDOF undisclosed Refractive  Technology , 4 point fixation -4 closed loops-.

Toric Customized Model has according to diopter possibility to correct astigmatism up to 15D in 0,25D steps.

NB : An AAO Task Force consensus statement requires EDOF IOLs to be within one line of BCVA of monofocal IOLs; to have 0.5D more of defocus than a monofocal at 20/30 level (therefore, approximately 1.25D defocus), and 50% patients to be better than 20/30.

Eye Max Mono for AMD (Care Group)

“The innovative technology and unique optics of the EyeMax lens diverts images away from the damaged part of the eye and enhances them to the healthy parts, leading to a significant improvement of vision for patients. The shape of the Eyemax Lens redirects the same high quality image at every point of the retina, leaving the selection of the best alternative macula to the human brain.” -so called “Proprietary Hyper-Wavefront Modified Optics by Optical Physist P Artal. Concept by Dr B Qureshi.

The Lens is combined with high + Specs to produce magnification.

Refractive Target +3D : 10% Mag,   +6D  20% mag (+10 to 30%)

To obtain IOL visit www.londoneyehospitalpharma.com

EYECRYL Lens for Phakic Eyes (Biotech)

Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm

Optic Size 4.65mm to 5.5mm according to dioptric correction

Range -3D to -23.0 D

EYECRYL Toric Lens for Phakic Eyes (Biotech)

Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm

Optic Size 4.65mm to 5.5mm according to dioptric correction

Range -3D to -23.0 D

Femtis Comfort FB-313 MF15 -Oculentis

EDOF adding +1,50D bisegmented design, one piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm. Femto Capsulorhexis “ready” IOL

Femtis FB-313 -Oculentis

One piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm.