Aniridia Implant Type 67G Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 5.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle. Also without Optic Available.

NB Intraop support of the IOL with Long Prolene Needle (Dr Sundmacher et al) https://www.youtube.com/watch?v=ucrk-EVDdMU

Aniridia Implant Type 67L Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 3.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle Opening in the diaphragm inferiorly for the injection of Vitreous Fluid Substitutes/ inferior iridotomy for silicone oil.

Aniridia Implant Type 68 Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 4.5 mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle

Artis PL E (Cristalens)

hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)

ARTIS PL M (Cristalens)

Preloaded Hydrophobic Acrylic Bifocal IOL for  for < 2.20mm incision Surgery, with  Aspherical posterior  Surface (Aberration Compensating) with near Add +3.00D (standard) or +2.50 (on request) , from France and IOLART (GR/CY)

ARTIS T PL E (Cristalens)

Hydrophobic Acrylic Toric IOL for  for < 2.20mm incision Surgery, with  Aspherical posterior  Surface (Aberration Neutral), from France and IOLART (GR/CY)

Artis Y PL (Cristalens)

yellow tinted hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)

AS-6D iDIFF Plus -yellow tinted hydrophilic- IOL R Cloop or P Plate -(Care Group)

“iDIFF Plus is a newer generation refractive-diffractive presbyopic IOL with an increasing step height diffractive pattern combined with increased step angulation between transition zones, resulting in superior optical quality for both distance and near. The design enables balanced distribution of light (60/40 light distribution for far and near respectively) and higher MTF values, which increases contrast sensitivity in all lighting conditions and reduces the effects of scattered light, such as persistent glare and haloes and is pupil independent.” copied from website.

Comes as iDiff R (C-loop haptics)  and iDiff P (plate) in 3 Adds +4.00/ +3.50/ +3.00 

ASPIRA aA / aAY -Monofocal HumanOptics

One piece  hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive technology. For capsular bag fixation. Infinite Spherical  Correctiuon -20D to +60D …aAY: with yellow Chromophore

ASPIRA-aQA HumanOptics

One piece  hydrophilic Acrylic plate  lens with 4closed loop Haptics.  Aspherical Optics  and 6.0 mm optical Zone. For capsular bag fixation.

ASPIRA-aQA HumanOptics

One piece  hydrophilic Acrylic plate  lens with 4closed loop Haptics.  Aspherical Optics  and 6.0 mm optical Zone. For capsular bag fixation.

ASPIRA-aXA HumanOptics

One piece plate hydrophilic Acrylic lens with aspherical Optics and very large 7mm Optic for capsular bag fixation

Axis Quadraloop Toric (Omni Lens)

one piece Hydrophilic acrylic with 4 haptic fixation and astigmatism control T3 (1,5 D -IOL Plane) to T9 (6.0D IOL Plane) -7 models

online Calculator www.omnitoric.in