Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia in pseudophakia. The IOL is supplied with a Rayner Injector.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Add +3,5D at IOL plane.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Bifocal Add +3,5D at IOL plane.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia (Sphere and astigmatism) in pseudophakia. The IOL is supplied with a Rayner Injector for incisions <2.7mm.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Trfocal Add +1.75D and 3,5D at IOL plane.
The Synchrony IOL (Visiogen, Abbott Medical Optics, AMO, Santa Ana, Calif.) was a single-piece dual-optic, silicone lens designed to mimic the natural lens. It had a 5.5 mm high plus anterior optic of +32 D, coupled to a 6.0 mm negatively powered posterior optic. The concept is that these two lenses are separated by a spring-activated mechanism. The haptics separate the lenses at a given distance under constriction of the capsule, and during relaxation of the capsule following accommodative effort, anterior movement of the positive anterior optic produces increased power for near tasks.
EDOF IOL on TECNIS Platform , posterior achromatic diffractive surface designed to reduce chromatic aberrations for enhanced image contrast, “echelette: feature to extend the range of vision.
EDOF IOL on TECNIS Platform , posterior achromatic diffractive surface designed to reduce chromatic aberrations for enhanced image contrast, “echelette: feature to extend the range of vision. Toric Correction from 1.50 to 3.75D (4 models) IOL Plane
One piece hydrophilic Acrylic lens with modified C loop Haptics and aspheric Optics Available also in Yellow Tint (811Y) Extended Dioptic Range to Hyperopia (+42D)
One piece hydrophilic Acrylic lens with modified C loop Haptics and aspheric Optics Available also in Yellow Tint (812Y) Extended Dioptic Range to Hyperopia (+42D) and large Optic (6,5mm)
One piece hydrophilic Acrylic lens with four modified closed loop Haptics and aspheric Optics Available also in Yellow Tint (820Y) Extended Dioptic Range to Hyperopia (+42D)
One piece hydrophilic Acrylic lens with four modified closed loop Haptics and aspheric Optics Available also in Yellow Tint (830Y) Extended Dioptic Range to Hyperopia (+42D)
One piece hydrophilic Acrylic lens with three modified closed loop Haptics and aspheric Optics Available also in Yellow Tint (851Y) Extended Dioptic Range to Hyperopia (+42D)
One piece hydrophilic Acrylic lens with modified C loops Haptics , aspheric Optics Available also in Yellow Tint (870Y) Extended Dioptic Range to Hyperopia (+42D)
One piece hydrophilic Acrylic lens with modified C loops Haptics , aspheric Optics Available also in Yellow Tint (872Y) Extended Dioptic Range to Hyperopia (+42D)
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive technology. For capsular bag fixation. Infinite Spherical/ Astigmatism Correctiuon -20D to +40D and astigmatism +1D to +20D
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive/diffractive technology offering +3.50D Add (IOL Plane). For capsular bag fixation. DOLA Technology: Diffractive Optic Local Asphericity –DOLA– meant to reduce Halo/ Dysphotopic Burden of Bifocal IOLs. Astigmatism Correctiuon +1D to +6.0 D IOL Plane.
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.Ok