BunnyLens AF (Hanita Lenses)
Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophilic Acrylic Lens from Israel.
Showing 29–56 of 85 results
Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophilic Acrylic Lens from Israel.
Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophobic Acrylic Lens from Israel.
“The innovative technology and unique optics of the EyeMax lens diverts images away from the damaged part of the eye and enhances them to the healthy parts, leading to a significant improvement of vision for patients. The shape of the Eyemax Lens redirects the same high quality image at every point of the retina, leaving the selection of the best alternative macula to the human brain.” -so called “Proprietary Hyper-Wavefront Modified Optics by Optical Physist P Artal. Concept by Dr B Qureshi.
The Lens is combined with high + Specs to produce magnification.
Refractive Target +3D : 10% Mag, +6D 20% mag (+10 to 30%)
To obtain IOL visit www.londoneyehospitalpharma.com
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
The FluidVision® Accommodating Intraocular Lens
Accommodation refers to the eye’s ability to dynamically adjust focus for clear vision at all distances. The FluidVision accommodating IOL from PowerVision contains a tiny amount of fluid inside the lens that moves in response to the natural muscle forces in the eye. The FluidVision lens provides True Accommodation™ by mimicking the eye’s natural accommodative process, changing shape and becoming thicker when the patient needs to see up close or thinner to see far away. (from Powervision Website)
Unlike the Nulens and the Lumina this 3rd investigational Device meant to change the Curvature in vivo is meant to be placed in the capsule.
This Device is designed to protect the Crystalline Space for current and future applications. Replacing the 260mg cataract with our current 15mg implant technology might not be the right solution for the future. It may even survive the era of Refractive Indexing. (Possible applications with Augmented Reality/ Zooming and Drug delivery Reservoir.
By ClarVistamedical -aquired by Alcon- comes a multicomponent IOL from Hydrophobic acrylic that the optic is adapted to the blue rim in situ. CE Marked.
bifocal l IOL from Germany (i-Medical Heidelberg) with diffractive +3.00 OR +3.5D OR +4.00 near, in Hydrophilic, Plate -p model or modified closed C-loops -r model-
trifocal IOL from Germany (i-Medical Heidelberg) with diffractive +1,8D intermediate and +3.5D near, in Hydrophilic, Plate Configuration.
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D”
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D” and astigmatism up to +10.0 D.
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
on line Calculator http:/www.ipciol.com/calc
“The engineers at LensGen® have developed a biomimetic device with the inherent ability to change curvature similar to the natural human lens. In doing so the team at LensGen® has taken the next step forward in developing a superior and breakthrough technology in the surgical treatment of cataracts and presbyopia.”
This patented Technology is based on a monofocal lens that has a curvature changing fluid compartment that actively changes shape. A Modified Ring is placed into the capsule and the optic is then inserted separetely.
Very Soft Material, amenable to flexure with ongoing bag construction post op !
The Lumina AIOL (AkkoLens International, Breda, The Netherlands) consists of 2 optical elements, capable of moving one on top of the other, and is implanted in the ciliary sulcus The lens is manufactured with an acrylic hydrophilic polymer material. The optics provides a fixed optical power: the anterior element is designed to provide 5 D while the posterior provides between 10 to 25 D, depending on the correction needed for the patient after the lens removal. Each one of the optics has an internal aspheric surface where its power increases linearly when the lens moves. Therefore, when the eye accommodates and the ciliary muscle contracts, the optics of the lens change their longitudinal position, passing one over the other thereby resulting in an increase of the dioptric power of the lens, focusing the light for the near distance and providing accommodation to the patient. J Alio et al, 2017