Lentis L-302-1
One piece hydrophilic Acrylic lens with modified C loop Haptics and spherical Optics
Showing 141–168 of 303 results
One piece hydrophilic Acrylic lens with modified C loop Haptics and spherical Optics
One piece hydrophilic plate Acrylic lens and spherical Optics for capsular bag fixation
One piece hydrophilic Acrylic lens with modified C loop Haptics and Biaspherical Optics for capsular bag fixation
One piece hydrophilic plate Acrylic lens and Biaspherical Optics for capsular bag fixation
One piece hydrophilic plate Acrylic lens and Biaspherical Optics for capsular bag fixationexhibits extra UV protection in violet light
One piece hydrophilic plate Acrylic lens and Biaspherical Optics compensating Cornea Asphericity for capsular bag fixation
One piece hydrophilic Acrylic lens with modified C loop Haptics and Biaspherical Optics for capsular bag fixationwith UV absorbing additional violet light filter
One piece plate hydrophilic Acrylic lens with Aspheric Optic offering infinite options for Astigmatism Control (manufactured to order with 0,01dpt accuracy) Correcting up to +12.0D of Astigmatism
One piece plate hydrophilic Acrylic lens with Aspheric Optic offering 7 standard options of Astigmatism Correction, Correcting from 0,75D in cornea Plane…to +5.25D Cornea Plane.
One piece plate hydrophilic Acrylic lens with Aspheric Optic offering infinite options for Astigmatism Control (manufactured to order with 0,01dpt accuracy. Sph+cyl <40D) Correcting up to +12.0D of Astigmatism. This model also has a Violet Light Filter
One piece hydrophilic Acrylic lens with 4 open loop haptics with aspherical surface fror Capsular, sulcus and Sulcus-Sclera fixation. Enlarged Haptics for possible Suture Fixation
One piece hydrophilic Acrylic lens with 4 open loop haptics with aspherical surface fror Capsular, sulcus and Sulcus-Sclera fixation. Enlarged Haptics for possible Suture Fixation
Hydrophobic Acrylic preloaded IOL for 3.00mm incision Surgery, with posterior Surface Aspheric SA-negative with +41.0D in 3 sizes, 12.00mm/ 13.00mm/ 14.00mm from France and IOLART (GR/CY)
Hydrophilic Acrylic for <2.00mm incision Surgery, with posterior Surface Aspheric SA-neutral, from France and IOLART (GR/CY)
The Lumina AIOL (AkkoLens International, Breda, The Netherlands) consists of 2 optical elements, capable of moving one on top of the other, and is implanted in the ciliary sulcus The lens is manufactured with an acrylic hydrophilic polymer material. The optics provides a fixed optical power: the anterior element is designed to provide 5 D while the posterior provides between 10 to 25 D, depending on the correction needed for the patient after the lens removal. Each one of the optics has an internal aspheric surface where its power increases linearly when the lens moves. Therefore, when the eye accommodates and the ciliary muscle contracts, the optics of the lens change their longitudinal position, passing one over the other thereby resulting in an increase of the dioptric power of the lens, focusing the light for the near distance and providing accommodation to the patient. J Alio et al, 2017
Designed by Dr Masket as a possible solution to Dysphotopic Phenomena. Recommended to keep Iris in Miosis for first 72H to avoid iris capturing
One piece hydrophilic Acrylic plate lens, aspherical Optics and optical Zone from 5,5 to 7.0 according to dioptic correction required . For capsular bag fixation.