Monofocal

Showing 281–303 of 303 results

type 81F PMMA LENS Morcher

one piece PMMA lens (13.0 mm) with 7.0 mm Optic. Primary for in the Bag Fixation/ Sulcus for Open Sky Approach.

Type 89A “Bag in Lens -Tassignon” -Morcher

one piece hydrophilic  Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon  needs dedication and proficiency performing PCCC -the “right” way

 

Type 89A TORIC “Bag in Lens -Tassignon” -Morcher

one piece hydrophilic  Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon  needs dedication and proficiency performing PCCC -the “right” way. This Version corrects Astigmatism up to +8,00D.

 

Type 89D “Bag in Lens -Tassignon” -Morcher

one piece hydrophilic  Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon  needs dedication and proficiency performing PCCC -the “right” way. This Model is for Short/ Pediatric Cases of Eyes <18mm and WTW <10mm.

 

Type 89F “Bag in Lens -Tassignon” -Morcher

one piece hydrophilic  Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon  needs dedication and proficiency performing PCCC -the “right” way. This Model is for cases requiring combined Cataract/ Vitrectomy Surgery in Eyes with Large Pupils

 

type 92 B Monofocal Hydrophilic Morcher

one piece hydrophilic  Acrylic lens with large C-loop  Haptics and large Optic 7.0mm,  For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6

type 92 C Monofocal Hydrophilic Morcher

one piece hydrophilic  Acrylic lens with 4 closed loop haptics for bag fixation only.  Overall Length 10,5mm-11.0mm. Optic Diameter 5,5mm to 6.5mm.  MICS Incision. Recommended A Constant for sclera fixation 120.6

type 92 G Monofocal Hydrophilic Morcher

one piece hydrophilic  Acrylic lens with large C-loop  Haptics and large Optic of 6.5mm,  For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6

type 92 S Monofocal Hydrophilic Morcher

one piece hydrophilic  Acrylic lens with large C-loop  Haptics,  For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6

type 97 B Monofocal Hydrophilic Morcher

one piece hydrophilic  Acrylic lens with 4 closed loop haptics for bag fixation only.  Overall Length 10,5mm-11.0mm. Optic Diameter 5,5mm to 6.5mm.  MICS Incision. Recommended A Constant for sclera fixation 120.6

Verisyse Phakic IOL

Iris fixated IOL designed for use in phakic Eyes. In our opinion the 5.00 OZ is more versatile and preferred in myopia without significant astigmatism.

 

Vista Lens (Vista Ocular)

 

Vista Ocular (Ohio, US), is developing an innovative technology to bypass pupillary and ciliary muscle movement, and target the muscle’s action potential as the accommodative signal. The technology is patented and more patents are pending. The company is currently in the process of testing an in-vivo sensor system for the detection of the ciliary muscle’s action potential. This design also incorporates rechargeable battery power with a flexible lens system to change optical power in a variable fashion (Figure 3). Along with Elenza are the 2 US based start-ups that aim to develop a electronic IOL

 

Vivinex Toric XY1A

preloaded Hydrophobic Acrylic (Vivinex) with Aspheric Design with  Blue Light Filtration correcting 1D to 6D Astigmatism (IOL Plane)

ZEISS AT TORBI 709M/MP

Preloaded plate bitoric  Hydrophilic Implant with  Spherical Aberration Contol. (SA neutral) MP _ preloaded