no

Showing 85–112 of 162 results

Partial Aniridia Implant Type 67D Morcher

total Diameter 13.5 mm.  Requires fair incision of >7.0 mm.  Pupillary Aperture 3.5 mm. With positioning holes for intrasleral fixation through sutures (9-0 Prolene on Spatula needle)

Partial Aniridia Implant Type 67E Morcher

total IOL Diame ter 13.5 mm. Requires fair incision of >8.0 mm.  Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation. (9-0 Prolene-spatula Needle)

Partial Aniridia Implant Type 68C Morcher

total IOL Diameter 14.00  mm. Requires fair incision of >7.0 mm.  Pupillary Aperture 3.5 mm. Two positioning holes in each haptic for suture to sclera fixation.

Partial Aniridia Implant Type 94C Morcher

total IOL Diame ter 13.5.00  mm. Requires fair incision of >8.0 mm.  Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation.

PMMA Alcon Lenses -Anterior Chamber- All 6 Sizes

All the Available PMMA Models from Alcon for Use in the Anterior Chamber. All require large incisions (5.7mm). MUST Follow Sizing Guidance ! 6 Models Available ….

For detailed description visit the site

https://www.myalconstore.com/education-resources/surgical-product-information/

 

RayOne Aspheric IOL RAO600C (Rayner)

Preloaded Hydrophilic (Rayacryl-26% H2O)  IOL with Anterior Aberration Neutral Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).

RayOne Trifocal IOL RAO603F (Rayner)

Preloaded Hydrophilic (Rayacryl-26% H2O)  IOL with Anterior Aberration Neutral Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).

Scleral Suturefree IOL Carlevale FIL SSF TORIC (Soleko)

Peculiar looking suturefree IOL for Fixation under scleral flaps throygh Trascleral plugs. Customized optic to provide toricity control at 0,25D steps! Injector: Medical Viscojet 2.2 or 2.7 . As per Company 2 week delivery time.

Watch the video!

SeeLens AF (Hanita Lenses)

Designed on Zemax for optimized MDF performance this is a conventional c loop aspheric one piece Hydrophilic Acrylic Lens from Israel.

SeeLens HP (Hanita Lenses)

Designed on Zemax for optimized MDF performance this is a conventional c loop aspheric one piece Hydrophobic Acrylic Lens from Israel.

SofPort AO LI61AO/ SofPort LI61SE

3-piece lens with Silicone aspheric neutral Optics (AO) or Spheric Optics (SE) . Because of the Silicone we recommend it is avoided in Complicated Surgery.

Sulcoflex Aspheric IOL 700L (Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia in pseudophakia. The IOL is supplied with a Rayner Injector.

Sulcoflex Multifocal IOL 653F(Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision).  Add +3,5D at IOL plane.

Sulcoflex Trifocal IOL 703F (Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Trfocal Add +1.75D and 3,5D at IOL plane.