FIL 611S SACSOL IOL Prime (Soleko)
Hydrophilic monofocal one Piece IOL with aspheric Optics for in the bag/ sulcus and sclera fixation through sutures
Showing 57–84 of 162 results
Hydrophilic monofocal one Piece IOL with aspheric Optics for in the bag/ sulcus and sclera fixation through sutures
Hydrophilic monofocal one Piece IOL with aspheric Optics 6/13 optic-overall length
one piece hydrophilic IOL where the Optical Element is connected to the Supporting Annulus through a Helix to theoretically allowe pivoting of the optic.
one piece hydrophilic IOL with Soleco’s 4 small diameter refractive central zone (trifocal) , designed for kids/ bag/ sulcus and sclera fixation.
one piece hydrophobic IOL with 4 point fixation -4 closed loops.
one piece hydrophobic IOL with 4 point fixation -4 closed loops -Preloaded .
one piece hydrophobic IOL with traditional design.
3-piece IOL with Hydrophobic Glistening Free and Spheric Optics (+0,2μ)
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D”
on line Calculator http:/www.ipciol.com/calc
One piece hydrophilic Acrylic lens with modified C loop Haptics and spherical Optics
One piece hydrophilic plate Acrylic lens and spherical Optics for capsular bag fixation
One piece hydrophilic Acrylic lens with modified C loop Haptics and Biaspherical Optics for capsular bag fixation
One piece hydrophilic plate Acrylic lens and Biaspherical Optics for capsular bag fixation
One piece hydrophilic plate Acrylic lens and Biaspherical Optics for capsular bag fixationexhibits extra UV protection in violet light
One piece hydrophilic plate Acrylic lens and Biaspherical Optics compensating Cornea Asphericity for capsular bag fixation
One piece hydrophilic Acrylic lens with modified C loop Haptics and Biaspherical Optics for capsular bag fixationwith UV absorbing additional violet light filter
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +1.5 Add and real Extended Dioptric Range
One piece hydrophilic Acrylic lens with 4 open loop haptics with aspherical surface fror Capsular, sulcus and Sulcus-Sclera fixation. Enlarged Haptics for possible Suture Fixation
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +2.0 Add
Note that only +3.0 Add is offered with a surface Optimizatuion for Paraxial Optics (MpusX)
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add
There is an older Version Mplus and a newer MpusX offering better paraxial optics (Additive Paraxial Asphericity) and “Surface Design Optimisation”. Note that this X is currently only available with the +3.0 segmented Optic
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add that may be placed in the eye in cases of inadequate capsular support
Hydrophobic Acrylic preloaded IOL for 3.00mm incision Surgery, with posterior Surface Aspheric SA-negative with +41.0D in 3 sizes, 12.00mm/ 13.00mm/ 14.00mm from France and IOLART (GR/CY)
Hydrophilic Acrylic for <2.00mm incision Surgery, with posterior Surface Aspheric SA-neutral, from France and IOLART (GR/CY)
Bifocal Lens adding +3.0 OR +4.0 at IOL plane, with 5,75mm (580F) or 6.25mm (630F) optical Zone. +3.00 Add offered from +14.0D to 30.0D Range (0,5D increments) and +4.00 Add offered from +10.0 D to +30.0D
Designed by Dr Masket as a possible solution to Dysphotopic Phenomena. Recommended to keep Iris in Miosis for first 72H to avoid iris capturing
One piece hydrophilic Acrylic plate lens, aspherical Optics and optical Zone from 5,5 to 7.0 according to dioptic correction required . For capsular bag fixation.
Requires fair incision of >7.0mm. Pupillary Aperture 3.5mm. Not for sclera fixation