no

Showing 57–84 of 162 results

IPCL V2.0 for Phakic Eyes (Care Group)

Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized.  Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D

on line Calculator   http:/www.ipciol.com/calc

IPCLD Presbyopic V2.0 for phakic Eyes(Care Group)

Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized.  Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D”

on line Calculator   http:/www.ipciol.com/calc

Lentis L-302-1

One piece hydrophilic Acrylic lens with modified C loop Haptics and spherical Optics

Lentis L-312 -Oculentis

One piece hydrophilic Acrylic lens with modified C loop Haptics and Biaspherical Optics for capsular bag fixation

Lentis L-313 -Oculentis

One piece hydrophilic plate Acrylic lens and Biaspherical Optics for capsular bag fixation

Lentis L-313Y -Oculentis

One piece hydrophilic plate Acrylic lens and Biaspherical Optics for capsular bag fixationexhibits extra UV protection in violet light

Lentis L-323 -Oculentis

One piece hydrophilic plate Acrylic lens and Biaspherical Optics compensating Cornea Asphericity for capsular bag fixation

Lentis LS-312Y -Oculentis

One piece hydrophilic Acrylic lens with modified C loop Haptics and Biaspherical Optics for capsular bag fixationwith UV absorbing additional violet light filter

Lentis LS-313-MF15 -Oculentis

One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +1.5 Add and real Extended Dioptric Range

Lentis LU-814 VR -Oculentis

One piece hydrophilic Acrylic lens with 4 open loop haptics with aspherical surface fror Capsular, sulcus and Sulcus-Sclera fixation. Enlarged Haptics for possible Suture Fixation

Lentis Mplus LS-313-MF20 -Oculentis

One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +2.0 Add

Note that only +3.0 Add is offered with a surface Optimizatuion for Paraxial Optics (MpusX)

Lentis Mplus LS-313-MF30/ Lentis MplusX LS-313 MF30 -Oculentis

One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add

There is an older Version Mplus and a newer MpusX offering better paraxial optics (Additive Paraxial Asphericity) and “Surface Design Optimisation”. Note that this X is currently only available with the +3.0 segmented Optic

Lentis-LU 814 MF30 -Oculentis

One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add that may be placed in the eye in cases of inadequate capsular support

LUCIS (Cristalens)

Hydrophilic Acrylic for <2.00mm incision Surgery, with posterior Surface Aspheric SA-neutral, from France and IOLART (GR/CY)

M-flex 580F/ 630F (Rayner)

Bifocal Lens adding +3.0 OR +4.0 at IOL plane, with 5,75mm (580F) or 6.25mm (630F) optical Zone.  +3.00 Add offered from +14.0D to 30.0D Range (0,5D increments) and +4.00 Add offered from +10.0 D to +30.0D

MC X11 ASP -Monofocal HumanOptics (Copy)

One piece  hydrophilic Acrylic plate  lens,  aspherical Optics  and optical Zone from 5,5 to 7.0 according to dioptic correction required . For capsular bag fixation.