no

Showing 1–28 of 162 results

AcrySof MA60 MA/ MN60 MA

White (MA) or Yellow spherical Optic, 3-piece IOL for LOW POWERS (-5.0D to +5.0D)only.  Also for Alternative Fixation Sulcus/Sclera/ Iris

AcrySof SA60 AT/ SN60 AT

White (MA) or Yellow spherical (SN) with aspheric Optic One piece Hydrophobic IOL, extended dioptric Range to +40.0 D.

Akreos AO60 (Bausch + Lomb)

Specialized Lens for MICS incisions less then 2.2 mm. Available in 10,5mm (for hyperopic) 10,7mm (Emmetropic) & 11.00mm (Myopic Eyes) sizes according to corresponding Power of the IOL.  Low index of refraction is supposed to limit Reflections from the IOL.. (As Adapt the Optic is Spheric- as AO it is  aspheric)

Akreos MICS M160L IOL (Bausch + Lomb)

Specialized Lens for MICS incisions less then 2.2 mm. Available in 10,5mm (for hyperopic) 10,7mm (Emmetropic) & 11.00mm (Myopic Eyes) sizes according to corresponding Power of the IOL.  Optic Zone is from 6,2mm in low Powered Lenses to 5.6mm in high powered Lenses  ( >22.0 D!)  Low index of refraction is supposed to limit Reflections from the IOL.

Aniridia Implant Type 67G Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 5.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle. Also without Optic Available.

NB Intraop support of the IOL with Long Prolene Needle (Dr Sundmacher et al) https://www.youtube.com/watch?v=ucrk-EVDdMU

Aniridia Implant Type 67L Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 3.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle Opening in the diaphragm inferiorly for the injection of Vitreous Fluid Substitutes/ inferior iridotomy for silicone oil.

Aniridia Implant Type 68 Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 4.5 mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle

Aniridia Implant Type 94A Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 6.5 mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle. Only without Optic Available. Sulcus with/without Sclera fixation. (For Existing Pseudophakia)

 

Artis PL E (Cristalens)

hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)

ARTIS PL M (Cristalens)

Preloaded Hydrophobic Acrylic Bifocal IOL for  for < 2.20mm incision Surgery, with  Aspherical posterior  Surface (Aberration Compensating) with near Add +3.00D (standard) or +2.50 (on request) , from France and IOLART (GR/CY)

Artis Y PL (Cristalens)

yellow tinted hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)

ASPIRA 3P-aVA Monofocal HumanOptics

3- piece  hydrophilic Acrylic lens with C-loop Highly Flexible Haptics, aspherical Optics and refractive technology. For capsular bag fixation.

ASPIRA aA / aAY -Monofocal HumanOptics

One piece  hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive technology. For capsular bag fixation. Infinite Spherical  Correctiuon -20D to +60D …aAY: with yellow Chromophore

ASPIRA-aQA HumanOptics

One piece  hydrophilic Acrylic plate  lens with 4closed loop Haptics.  Aspherical Optics  and 6.0 mm optical Zone. For capsular bag fixation.

ASPIRA-aQA HumanOptics

One piece  hydrophilic Acrylic plate  lens with 4closed loop Haptics.  Aspherical Optics  and 6.0 mm optical Zone. For capsular bag fixation.

ASPIRA-aXA HumanOptics

One piece plate hydrophilic Acrylic lens with aspherical Optics and very large 7mm Optic for capsular bag fixation