BunnyLens AF (Hanita Lenses)
Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophilic Acrylic Lens from Israel.
Showing 57–84 of 186 results
Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophilic Acrylic Lens from Israel.
Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophobic Acrylic Lens from Israel.
Based on the Crystalens Platform -Embedded Polymide haptics into the hinged Silicone Plate of the IOL. with Aspheric Optics. B+L will supply AO1UV (11,5mm) and AO2UV (12,0) for smaller/hyperopic and larger/myopic eyes respectively (From +17 0 to +27.0 in 0,25D steps!)
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive/diffractive technology offering +3.50D Add (IOL Plane). For capsular bag fixation. DOLA Technology: Diffractive Optic Local Asphericity –DOLA– meant to reduce Halo/ Dysphotopic Burden of Bifocal IOLs.
EDEN: Proprietary EDOF technology that excibits a unique exagerrated aspheric (central region 1mm- Instant Focus Technology), combined with a diffractive Zone (3.5mm) and Refractive (to 6mm) properties. One piece Hydrophilic acrylic with double closed loops IOL in two Sizes.
“The innovative technology and unique optics of the EyeMax lens diverts images away from the damaged part of the eye and enhances them to the healthy parts, leading to a significant improvement of vision for patients. The shape of the Eyemax Lens redirects the same high quality image at every point of the retina, leaving the selection of the best alternative macula to the human brain.” -so called “Proprietary Hyper-Wavefront Modified Optics by Optical Physist P Artal. Concept by Dr B Qureshi.
The Lens is combined with high + Specs to produce magnification.
Refractive Target +3D : 10% Mag, +6D 20% mag (+10 to 30%)
To obtain IOL visit www.londoneyehospitalpharma.com
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
EDOF adding +1,50D bisegmented design, one piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm. Femto Capsulorhexis “ready” IOL
One piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm.
Hydrophilic monofocal one Piece IOL with aspheric Optics
4-point support Hydrophilic monofocal one Piece IOL with aspheric Optics 6/11 optic-overall length
Hydrophilic monofocal one Piece IOL with aspheric Optics for in the bag/ sulcus and sclera fixation through sutures
Hydrophilic monofocal one Piece IOL with aspheric Optics 6/13 optic-overall length
Harmonis Top of the line individually Customized IOL, customizing % of Light intensity to Far Vision (40-80%), Intermiediate Vision (10-30%) and near Vision (10-48%). Proprietary EDOF technology that excibits a unique exagerrated aspheric (central region 1mm- Instant Focus Technology) combined with a diffractive Annulus to 3,7mm, monofocal (prob Aspheric) Refractive (to 6mm) properties. One piece Hydrophilic acrylic with double closed loops IOL in two Sizes.
one piece hydrophobic IOL with 4 point fixation -4 closed loops.
one piece hydrophobic IOL with 4 point fixation -4 closed loops -Preloaded .
one piece hydrophobic IOL with traditional design.
pecucliar hydrid of one piece to 3-piece IOL with proprietary Aspheric Optics (Aspheric Balanced Curve-ABC) , 360 square edge and zero haptic angulation
Aspheric IOL with particular one piece C Loop Design reinforced with PMMA
trifocal IOL from Germany (i-Medical Heidelberg) with diffractive +1,8D intermediate and +3.5D near, in Hydrophilic, Plate Configuration.
The Principle of the Accufocus intracorneal Implant -Kamra- realized in standard IOL technology
May be also appropriate for use in cases with corneal related macro aberrations
The “pinhole principle” is meant to increase depth of focus to about 3D. It has a non-diffractive 3.23mm diameter opaque PVDF mask with 1.36mm central aperture.
(NB Discuss possibility of Pulfrich Effect because of Dissimilar Intensity of Light between lights -consider dilating one eye only during consultation)
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D”
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D” and astigmatism up to +10.0 D.
on line Calculator http:/www.ipciol.com/calc