“The innovative technology and unique optics of the EyeMax lens diverts images away from the damaged part of the eye and enhances them to the healthy parts, leading to a significant improvement of vision for patients. The shape of the Eyemax Lens redirects the same high quality image at every point of the retina, leaving the selection of the best alternative macula to the human brain.” -so called “Proprietary Hyper-Wavefront Modified Optics by Optical Physist P Artal. Concept by Dr B Qureshi.
The Lens is combined with high + Specs to produce magnification.
EDOF adding +1,50D bisegmented design, one piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm. Femto Capsulorhexis “ready” IOL
Harmonis Top of the line individually Customized IOL, customizing % of Light intensity to Far Vision (40-80%), Intermiediate Vision (10-30%) and near Vision (10-48%). Proprietary EDOF technology that excibits a unique exagerrated aspheric (central region 1mm- Instant Focus Technology) combined with a diffractive Annulus to 3,7mm, monofocal (prob Aspheric) Refractive (to 6mm) properties. One piece Hydrophilic acrylic with double closed loops IOL in two Sizes.
pecucliar hydrid of one piece to 3-piece IOL with proprietary Aspheric Optics (Aspheric Balanced Curve-ABC) , 360 square edge and zero haptic angulation
The Principle of the Accufocus intracorneal Implant -Kamra- realized in standard IOL technology
May be also appropriate for use in cases with corneal related macro aberrations
The “pinhole principle” is meant to increase depth of focus to about 3D. It has a non-diffractive 3.23mm diameter opaque PVDF mask with 1.36mm central aperture.
(NB Discuss possibility of Pulfrich Effect because of Dissimilar Intensity of Light between lights -consider dilating one eye only during consultation)
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D”
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D” and astigmatism up to +10.0 D.
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
One piece hydrophilic Acrylic lens with modified C loop Haptics and Biaspherical Optics for capsular bag fixationwith UV absorbing additional violet light filter