FIL 611 T(oric) Review Premium IOL (Soleko)
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Showing 113–140 of 276 results
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Toric Customized Hydrophylic one Piece IOL. Axis of IOL to implanted always at 0-180.
Toric Customized Hydrophylic Multifocal Lens (customized sphere/ astigmatism) 0,25D steps. 4 concentric refractive rings!
Hydrophilic monofocal one Piece IOL with aspheric Optics for in the bag/ sulcus and sclera fixation through sutures
Hydrophilic monofocal one Piece IOL with aspheric Optics 6/13 optic-overall length
one piece hydrophilic IOL where the Optical Element is connected to the Supporting Annulus through a Helix to theoretically allowe pivoting of the optic.
preloaded Hydrophobic Acrylic IOL for in the bag placement
Harmonis Top of the line individually Customized IOL, customizing % of Light intensity to Far Vision (40-80%), Intermiediate Vision (10-30%) and near Vision (10-48%). Proprietary EDOF technology that excibits a unique exagerrated aspheric (central region 1mm- Instant Focus Technology) combined with a diffractive Annulus to 3,7mm, monofocal (prob Aspheric) Refractive (to 6mm) properties. One piece Hydrophilic acrylic with double closed loops IOL in two Sizes.
one piece hydrophobic IOL with 4 point fixation -4 closed loops.
one piece hydrophobic IOL with 4 point fixation -4 closed loops -Preloaded .
one piece hydrophobic IOL with traditional design.
Spheric white/ yellow IOL with particular one piece C Loop Design reinforced with PMMA
3-piece IOL with Hydrophobic Glistening Free Aproprietary Aspheric Optic (ABC-0,18μ) Also known as PC-60AD/PY-60AD.
pecucliar hydrid of one piece to 3-piece IOL with proprietary Aspheric Optics (Aspheric Balanced Curve-ABC) , 360 square edge and zero haptic angulation
Aspheric IOL with particular one piece C Loop Design reinforced with PMMA
3-piece IOL with Hydrophobic Glistening Free and Spheric Optics (+0,2μ)
bifocal l IOL from Germany (i-Medical Heidelberg) with diffractive +3.00 OR +3.5D OR +4.00 near, in Hydrophilic, Plate -p model or modified closed C-loops -r model-
trifocal IOL from Germany (i-Medical Heidelberg) with diffractive +1,8D intermediate and +3.5D near, in Hydrophilic, Plate Configuration.
InFO for Instant Focus: Proprietary EDOF technology that excibits a unique exagerrated aspheric (central region), combined with refractive diffractive properties. One piece Hydrophilic acrylic with double closed loops IOL in two Sizes.
The Principle of the Accufocus intracorneal Implant -Kamra- realized in standard IOL technology
May be also appropriate for use in cases with corneal related macro aberrations
The “pinhole principle” is meant to increase depth of focus to about 3D. It has a non-diffractive 3.23mm diameter opaque PVDF mask with 1.36mm central aperture.
(NB Discuss possibility of Pulfrich Effect because of Dissimilar Intensity of Light between lights -consider dilating one eye only during consultation)
The IOL K features a centrally located high negative powered portion (1.7mm) covering the central scotoma but not interfearing with the rest of the optical Zone thus -according to the company- not affecting the patients mobility so much. With High powered Positive Specs the Patients enjoys a mag to 3x from the combination of the negative powered central portion of the IOL and the Hyperopic Specs (Gallilean Telescope)