6.0mm

Showing 253–276 of 276 results

TORICADIFF-aA/ aA Yellow HumanOptics

One piece  hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive/diffractive technology offering +3.50D Add (IOL Plane). For capsular bag fixation. DOLA Technology: Diffractive Optic Local Asphericity –DOLA– meant to reduce Halo/ Dysphotopic Burden of Bifocal IOLs. Astigmatism Correctiuon +1D to +6.0 D IOL Plane.

type 25 PMMA LENS Morcher

one piece PMMA lens (13.5 mm) with 6.0 mm Optic. Primary for in the Bag Fixation/ Open Sky Approach.  Better Options Offered for Sulcus Fixation

type 65C PMMA LENS Morcher

one piece PMMA lens (13mm) with 6.0 mm Optic. Primary for in the Bag Fixation/ Open Sky Approach.  Better Options Offered for Sulcus Fixation

type 92 B Monofocal Hydrophilic Morcher

one piece hydrophilic  Acrylic lens with large C-loop  Haptics and large Optic 7.0mm,  For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6

type 92 C Monofocal Hydrophilic Morcher

one piece hydrophilic  Acrylic lens with 4 closed loop haptics for bag fixation only.  Overall Length 10,5mm-11.0mm. Optic Diameter 5,5mm to 6.5mm.  MICS Incision. Recommended A Constant for sclera fixation 120.6

type 92 S Monofocal Hydrophilic Morcher

one piece hydrophilic  Acrylic lens with large C-loop  Haptics,  For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6

Verisyse Phakic IOL

Iris fixated IOL designed for use in phakic Eyes. In our opinion the 5.00 OZ is more versatile and preferred in myopia without significant astigmatism.

 

Vivinex Toric XY1A

preloaded Hydrophobic Acrylic (Vivinex) with Aspheric Design with  Blue Light Filtration correcting 1D to 6D Astigmatism (IOL Plane)

ZEISS AT LARA toric 929M/MP

Diffractive, bitoric aspheric (aberration Neutral) Hydrophilic Acrylic,  Depth of Focus Extending by 0,95D and 1,90D.  MP _ preloaded

ZEISS AT LARA 929MP

Diffractive,  aspheric (aberration correcting) Hydrophilic Acrylic,  Depth of Focus Extending by 0,95D and 1,90D.  MP _ preloaded (BLUEMIXS 180)

ZEISS AT LISA 909M/MP

Bifocal, Diffractive, aspheric (aberration correcting) Hydrophilic Acrylic,  Near Add at IOL plane +3.75D  MP _ preloaded

ZEISS AT LISA toric 909M/MP

Bifocal, Diffractive, toric aspheric (aberration correcting) Hydrophilic Acrylic,  Near Add at IOL plane +3.75D  MP _ preloaded

ZEISS AT LISA tri (toric) 939MP preloaded

Trifocal, Diffractive, toric aspheric (aberration correcting) Hydrophilic Acrylic,  Intermediate Add +1.66D , Near Add at IOL plane +3.33D – IOL Plane. Preloaded only

ZEISS AT TORBI 709M/MP

Preloaded plate bitoric  Hydrophilic Implant with  Spherical Aberration Contol. (SA neutral) MP _ preloaded