Acrylic Hydrophobic

Showing 29–56 of 104 results

AS-6D iDIFF Plus -yellow tinted hydrophilic- IOL R Cloop or P Plate -(Care Group)

“iDIFF Plus is a newer generation refractive-diffractive presbyopic IOL with an increasing step height diffractive pattern combined with increased step angulation between transition zones, resulting in superior optical quality for both distance and near. The design enables balanced distribution of light (60/40 light distribution for far and near respectively) and higher MTF values, which increases contrast sensitivity in all lighting conditions and reduces the effects of scattered light, such as persistent glare and haloes and is pupil independent.” copied from website.

Comes as iDiff R (C-loop haptics)  and iDiff P (plate) in 3 Adds +4.00/ +3.50/ +3.00 

BunnyLens HP (Hanita Lenses)

Designed on Zemax for optimized MDF performance this is a plate aspheric one piece Hydrophobic  Acrylic Lens from Israel.

Clareon AutonoMe CNA0T0 -Alcon

one piece hydrophobic Acrylic monofocal IOL with aspheric optics, Preloaded with brilliant Single Use, C02 Propulsion System. Glistening Free.

CT LUCIA 211P

Preloaded single Piece hydrophobic C-loop Implant with heparinized Surface without Asphericity like 611.

CT LUCIA 611P

Preloaded single Piece hydrophobic C-loop Implant with heparinized Surface and Zeiss Unique Spheric (outer Area)/Aspheric (inner Area) profile. (ZO ZEISS Optic)

EAZ-Y (Cristalens)

yellow tinted hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)

Eye Max Mono for AMD (Care Group)

“The innovative technology and unique optics of the EyeMax lens diverts images away from the damaged part of the eye and enhances them to the healthy parts, leading to a significant improvement of vision for patients. The shape of the Eyemax Lens redirects the same high quality image at every point of the retina, leaving the selection of the best alternative macula to the human brain.” -so called “Proprietary Hyper-Wavefront Modified Optics by Optical Physist P Artal. Concept by Dr B Qureshi.

The Lens is combined with high + Specs to produce magnification.

Refractive Target +3D : 10% Mag,   +6D  20% mag (+10 to 30%)

To obtain IOL visit www.londoneyehospitalpharma.com

IOL Expert IC-8

The Principle of the Accufocus intracorneal Implant -Kamra- realized in standard IOL technology

May be also appropriate for use in cases with corneal related macro aberrations

The “pinhole principle”  is meant to increase depth of focus to about 3D. It has a non-diffractive 3.23mm diameter opaque PVDF mask with 1.36mm central aperture.

(NB Discuss possibility of Pulfrich Effect because of Dissimilar Intensity of Light between lights -consider dilating one eye only during consultation)