Aphakia / Cataract Surgery

Showing 197–224 of 317 results

Nulens Dynacurve IOL (Nulens ltd)

The NuLens Dynacurve accommodative IOL (NuLens, Ltd., Herzliya Pituah, Israel) consists of: 1) polymethyl methacrylate (PMMA) haptics that are designed to be placed in the ciliary sulcus; 2) a PMMA anterior reference plane that provides distance vision correction; 3) a small chamber containing a solid silicone gel and 4) a posterior piston with an aperture in the center.

Such IOL prototypes, even with silicone gel of a relatively low refractive index (1.40), have been shown in a primate eye to deliver more than 40.00 D of accommodation using only 500 µm of vertical diaphragm displacement. No wonder the principle was evaluated clinically in AMD Patients, providing additional evidence regarding the Concept of possible extreme Accommodation. This Prototype of lens required a 9mm incision to be inserted in the sulcus/bag.

 

OVERVIEW AS natural Hydrophobic IOL (i Medical)

Hydrophobic acrylic material natural yellow tinted (resembling a natural 40 yo crystalline lens -as per it’s Germany-Heidelberg located manufacturer ). Also available in a fully preloaded Version.

Partial Aniridia Implant Type 67D Morcher

total Diameter 13.5 mm.  Requires fair incision of >7.0 mm.  Pupillary Aperture 3.5 mm. With positioning holes for intrasleral fixation through sutures (9-0 Prolene on Spatula needle)

Partial Aniridia Implant Type 67E Morcher

total IOL Diame ter 13.5 mm. Requires fair incision of >8.0 mm.  Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation. (9-0 Prolene-spatula Needle)

Partial Aniridia Implant Type 68C Morcher

total IOL Diameter 14.00  mm. Requires fair incision of >7.0 mm.  Pupillary Aperture 3.5 mm. Two positioning holes in each haptic for suture to sclera fixation.

Partial Aniridia Implant Type 94C Morcher

total IOL Diame ter 13.5.00  mm. Requires fair incision of >8.0 mm.  Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation.

PMMA Alcon Lenses -Anterior Chamber- All 6 Sizes

All the Available PMMA Models from Alcon for Use in the Anterior Chamber. All require large incisions (5.7mm). MUST Follow Sizing Guidance ! 6 Models Available ….

For detailed description visit the site

https://www.myalconstore.com/education-resources/surgical-product-information/

 

PreciSight Multicomponent IOL (Infinitevisionoptics)

 

This is a multicomponent Lens system with two Optics, one of which can be easily exchanged, may work for pediatric cases and cases anticipated to have ametropia postop. Online calculator . French CE marked  technology.

Posterior Optical Plate Aspheric Hydrophobic, Anterior Plate is Hydrophilic with Spherical Optic, Both are 5.7mm diameter. Both can be made clear or yellow colored.

 

https://www.youtube.com/watch?v=-k7e5ZZNVDE

RayOne Aspheric IOL RAO600C (Rayner)

Preloaded Hydrophilic (Rayacryl-26% H2O)  IOL with Anterior Aberration Neutral Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).

RayOne Trifocal IOL RAO603F (Rayner)

Preloaded Hydrophilic (Rayacryl-26% H2O)  IOL with Anterior Aberration Neutral Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).