Acriva UDB 625 (VSY Biotechnology)
Hydrophilic IOL one Piece from VSY – High Definition Optic.
Showing 29–56 of 317 results
Hydrophilic IOL one Piece from VSY – High Definition Optic.
Hydrophilic IOL one Piece from VSY. Premium Design and Material
one piece hydrophobic acrylic with traditional C haptic design. High Abbe Number
one piece hydrophobic acrylic with modified C haptic design. High Abbe Number
one piece hydrophobic Acrylic IOL , trifocal refractive diffractive design, with +2.17D add and +3.25D add (IOL Plane)
one piece hydrophobic Acrylic IOL , trifocal refractive diffractive design, with Astigmatism control 1.0D to 3.75D (IOL-Plane)
one piece hydrophobic Acrylic monofocal IOL with aspheric optics, preloaded
one piece hydrophobic Acrylic monofocal IOL with aspheric optics, preloaded
one piece hydrophobic Acrylic monofocal IOL with aspheric optics and Astigmatism cotrol from 1D to 6D (IOL Plane)
White (MA) or Yellow spherical Optic, 3-piece IOL for LOW POWERS (-5.0D to +5.0D)only. Also for Alternative Fixation Sulcus/Sclera/ Iris
White (MA) or Yellow spherical (SN) with aspheric Optic One piece Hydrophobic IOL, extended dioptric Range to +40.0 D.
5 different Models with 6 to 6,5mm OZ, PMMA Haptics for alternative Fixation.
For more info visit:
www.myalconstore.com/education-resources/surgical-product-information/
Specialized Lens for MICS incisions less then 2.2 mm. Available in 10,5mm (for hyperopic) 10,7mm (Emmetropic) & 11.00mm (Myopic Eyes) sizes according to corresponding Power of the IOL. Low index of refraction is supposed to limit Reflections from the IOL.. (As Adapt the Optic is Spheric- as AO it is aspheric)
Specialized Lens for MICS incisions less then 2.2 mm. Available in 10,5mm (for hyperopic) 10,7mm (Emmetropic) & 11.00mm (Myopic Eyes) sizes according to corresponding Power of the IOL. Optic Zone is from 6,2mm in low Powered Lenses to 5.6mm in high powered Lenses ( >22.0 D!) Low index of refraction is supposed to limit Reflections from the IOL.
Iris fixated IOL from India. From the Care Group.
total presbyopia correcting, one piece IOL (TRIFOCAL IOL) with alleged impressive light transmission 91.4%.
material: smart matrix, interpenetrating polymer network of hydrophobic and hydrophilic acrylic
haptic design features : 4 suspensive corner fins, 2 wide OVD aspiration holes, 4 positioning holes
Addition: +3.55D at 35cm , +1.77 D at 70cm
Company claims their design with “Fourier” Designed “reverse Apodization” will improve 24h light distribution and Dysphotopic symptoms. -Height of harmonic waves (no diffractive steps) INCREASE from center to periphery!
Requires huge incision of >10.0mm. Pupillary Aperture 3.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle
Requires huge incision of >10.0mm. Pupillary Aperture 5.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle. Also without Optic Available.
NB Intraop support of the IOL with Long Prolene Needle (Dr Sundmacher et al) https://www.youtube.com/watch?v=ucrk-EVDdMU
Requires huge incision of >10.0mm. Pupillary Aperture 3.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle Opening in the diaphragm inferiorly for the injection of Vitreous Fluid Substitutes/ inferior iridotomy for silicone oil.