Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D” and astigmatism up to +10.0 D.
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
One piece plate hydrophilic Acrylic lens with Aspheric Optic offering infinite options for Astigmatism Control (manufactured to order with 0,01dpt accuracy) Correcting up to +12.0D of Astigmatism
One piece plate hydrophilic Acrylic lens with Aspheric Optic offering 7 standard options of Astigmatism Correction, Correcting from 0,75D in cornea Plane…to +5.25D Cornea Plane.
One piece plate hydrophilic Acrylic lens with Aspheric Optic offering infinite options for Astigmatism Control (manufactured to order with 0,01dpt accuracy. Sph+cyl <40D) Correcting up to +12.0D of Astigmatism. This model also has a Violet Light Filter
One piece hydrophilic Acrylic lens with 4 open loop haptics with aspherical surface fror Capsular, sulcus and Sulcus-Sclera fixation. Enlarged Haptics for possible Suture Fixation
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +1.50D Add and customized Sphere and Astigmatism Correction. This Model offers additional UV-protection (Violet-Filter)
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +2.0 Add and customized Sphere and Astigmatism Correction.This Version has additional UV protectuion (Violet Filter)
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add and customized Sphere and Astigmatism Correction
There is an older Version Mplus and a newer MpusX offering better paraxial optics (Additive Paraxial Asphericity) and “Surface Design Optimisation”. Note that this X is currently only available with the +3.0 segmented Optic
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add and customized Sphere and Astigmatism Correction. This Version has additional UV pritection (Violet-filter)
There is an older Version Mplus and a newer MpusX offering better paraxial optics (Additive Paraxial Asphericity) and “Surface Design Optimisation”. Note that this X is currently only available with the +3.0 segmented Optic
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add that may be placed in the eye in cases of inadequate capsular support. Individualized Sphere and Astigmatism correction (up to +12.0D)
Bifocal Lens adding +3.0 OR +4.0 at IOL plane, with 5,75mm (580F) or 6.25mm (630F) optical Zone. +3.00 Add offered from +14.0D to 30.0D Range (0,5D increments) and +4.00 Add offered from +10.0 D to +30.0D
Peculiar looking suturefree IOL for Fixation under scleral flaps throygh Trascleral plugs. Customized optic to provide toricity control at 0,25D steps! Injector: Medical Viscojet 2.2 or 2.7 . As per Company 2 week delivery time.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Bifocal Add +3,5D at IOL plane.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia (Sphere and astigmatism) in pseudophakia. The IOL is supplied with a Rayner Injector for incisions <2.7mm.
EDOF IOL on TECNIS Platform , posterior achromatic diffractive surface designed to reduce chromatic aberrations for enhanced image contrast, “echelette: feature to extend the range of vision. Toric Correction from 1.50 to 3.75D (4 models) IOL Plane
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.Ok