FINEVISION Trifocal Hydrophobic/ PhysIOL (Pod F GF)
preloaded Hydrophobic Acrylic IOL for in the bag placement
Showing 29–56 of 83 results
preloaded Hydrophobic Acrylic IOL for in the bag placement
one piece hydrophobic IOL with 4 point fixation -4 closed loops.
one piece hydrophobic IOL with 4 point fixation -4 closed loops -Preloaded .
one piece hydrophobic IOL with traditional design.
3-piece IOL with Hydrophobic Glistening Free Aproprietary Aspheric Optic (ABC-0,18μ) Also known as PC-60AD/PY-60AD.
3-piece IOL with Hydrophobic Glistening Free and Spheric Optics (+0,2μ)
The Principle of the Accufocus intracorneal Implant -Kamra- realized in standard IOL technology
May be also appropriate for use in cases with corneal related macro aberrations
The “pinhole principle” is meant to increase depth of focus to about 3D. It has a non-diffractive 3.23mm diameter opaque PVDF mask with 1.36mm central aperture.
(NB Discuss possibility of Pulfrich Effect because of Dissimilar Intensity of Light between lights -consider dilating one eye only during consultation)
Very Soft Material, amenable to flexure with ongoing bag construction post op !
Hydrophobic Acrylic preloaded IOL for 3.00mm incision Surgery, with posterior Surface Aspheric SA-negative with +41.0D in 3 sizes, 12.00mm/ 13.00mm/ 14.00mm from France and IOLART (GR/CY)
The Lumina AIOL (AkkoLens International, Breda, The Netherlands) consists of 2 optical elements, capable of moving one on top of the other, and is implanted in the ciliary sulcus The lens is manufactured with an acrylic hydrophilic polymer material. The optics provides a fixed optical power: the anterior element is designed to provide 5 D while the posterior provides between 10 to 25 D, depending on the correction needed for the patient after the lens removal. Each one of the optics has an internal aspheric surface where its power increases linearly when the lens moves. Therefore, when the eye accommodates and the ciliary muscle contracts, the optics of the lens change their longitudinal position, passing one over the other thereby resulting in an increase of the dioptric power of the lens, focusing the light for the near distance and providing accommodation to the patient. J Alio et al, 2017
preloaded Hydrophobic Acrylic IOL for in the bag placement
One Piece hydrophilic acrylic IOL with 2 Mod. C loops (Acrysof -like).
total Diameter 13.5 mm. Requires fair incision of >7.0 mm. Pupillary Aperture 3.5 mm. With positioning holes for intrasleral fixation through sutures (9-0 Prolene on Spatula needle)
total IOL Diame ter 13.5 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation. (9-0 Prolene-spatula Needle)
All the Available PMMA Models from Alcon for Use in the Anterior Chamber. All require large incisions (5.7mm). MUST Follow Sizing Guidance ! 6 Models Available ….
For detailed description visit the site
https://www.myalconstore.com/education-resources/surgical-product-information/
Six Old Fashioned PMMA IOLs Models from Alcon requiring large incisions. For Reference and special cases only.
non Glistening Hydrophobic material (Originally from MBI) with superb clarity/ optical performance. One Piece Lens with modified two open loops.
preloaded Hydrophobic Acrylic IOL for in the bag placement
Designed on Zemax for optimized MDF performance this is a conventional c loop aspheric one piece Hydrophilic Acrylic Lens from Israel.
Designed on Zemax for optimized MDF performance this is a conventional c loop aspheric one piece Hydrophobic Acrylic Lens from Israel.
monofocal, 3-pieceACRYLIC IOL (13mm) with Aspheric correcting Optics and OptiEdge Design.
the ME Model has an overall diameter 13.5mm