Showing 29–56 of 56 results

IPCLDT Presbyopic Toric V2.0 for phakic Eyes (Care Group)

Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized.  Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D” and astigmatism up to +10.0 D.

on line Calculator   http:/www.ipciol.com/calc

IPCLT V2.0 for Phakic Eyes (Care Group)

Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized.  Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D

on line Calculator   http:/www.ipciol.com/calc

MethylVisc 2.0% (OVD) Rayner

Typical  2.0% HPMC, in a 2.0 ml Syringe and 23G Cannula. Low Viscosity with maximal Coating Effect 2600-7.00mPa / Dispersive

MonoBlue SafR (ARCAD)

from the French producer of several VR products comes MonoBlue SafR especially for anterior Segment Surgery (0,55%)

myVisc Bio (Oculentis)

1,2% NaHA with high Molecular Weight (3 mill Daltons) and quite low  Viscosity: 65.000mPs, Zero shear rate, in 1,2 ml syringe. 27G cannula.

myVisc BioPlus (Oculentis)

1,8% NaHA with high Molecular Weight (3 mill Daltons) and quite high  Viscosity: 210.000mPs, Zero shear rate, in 1,2 ml syringe. 25G cannula.

myVisC Hyal 1.0 (Oculentis)

1% NaHA with 1.0Million Daltons Molecular Weight and high Viscosity: 1 million cPs Zero shear rate, in 0,55ml and 0,85ml syringe. 27G cannula.

Oasis Iris Retractors

invaluable devices to strech and retain iris during surgery. Use at least 5 in each case. It;s worth the time investment.

30 pieces per box.

Ophteis (OVD) Rayner

Animal Origin, 1% NaHA, High molecular Weight (5mill) resulting in high Viscosity and Pseudoplasticity resulting in good space creation and controlled IOL injection and facilitating easy removal at the end of Surgery

Ophteis + (OVD) Rayner

Animal Origin, 1,4% NaHA, High molecular Weight (5mill) resulting in high Viscosity and Pseudoplasticity resulting in good space creation and controlled IOL injection and facilitating easy removal at the end of Surgery

Ophteis BIO 1,6% (OVD) Rayner

Obtained by Biofermentation NOT Anmal Origin, 1,6% NaHA, High molecular Weight -Dalton (3mill) resulting in quite high Viscosity and Pseudoplasticity resulting in good space creation and controlled IOL injection and facilitating easy removal at the end of Surgery. 1,1 ml Syringe Volume , 27 G Cannula!

Classified by Company as Cohesive

Ophteis BIO 1,8% (OVD) Rayner

Obtained by Biofermentation NOT Anmal Origin, 1,8% NaHA, High molecular Weight -Dalton (3mill) resulting in good cohesivity at low shear-rates (Zero Shear Viscosity ~600.000 mPas- but also strong coating ability (improved dispersive Properties) Easy removal at the end of Surgery. 1,1 ml Syringe Volume , 27 G Cannula!

Classified by Company as Cohesive

Ophteis BIO 3% (OVD) Rayner

Obtained by Biofermentation NOT Anmal Origin, 3.0% NaHA, Molecular Weight -Dalton (0,75mill) resulting in best possible Coating Ability (and Endothelium Protection) even at high shear-rates (Zero Shear Viscosity only ~30.000 mPas- but also strong coating ability (improved dispersive Properties) Easy removal at the end of Surgery. 1,1 ml Syringe Volume , 25 G Cannula!

Classified by Company as Dispersive

Ophteis FR Pro (OVD) Rayner

the bio-engineered composition of NaHA and Sorbitol transforms the 2% NaHA dispersive solution into aviscous cohesive. (ViscousCohesive) Average Molecular Weight 1.8Mda

OphteisMax B-OPX085 (OVD) Rayner

Animal Origin, 2,5% NaHA, High molecular Weight -Dalton (4mill) resulting in high Viscosity and Pseudoplasticity resulting in good space creation and controlled IOL injection and facilitating easy removal at the end of Surgery. 0,85ml Syringe Volume , 25 G Cannula!

Classified by Company as Visco-Adaptive (under Stress it behaves like dispersive)

Pe-Ha-Blue PLUS (ALBOMED)

ALBOMED specializes in Viscoelastic Product from Rooster Comb extract and Biofermentation as well as HPMC. Trypan Blue addition was patented and introduced in 2015. (NaHA 1.7%, MW between 1-2 mill Dalton) Zero Shear Viscosity unknown.

Pe-Ha-Glide (ALBOMED)

ALBOMED specializes in Viscoelastic Product from Rooster Comb extract and Biofermentation as well as HPMC. This 2% HPMC formulation in monodose formulation  is specialized in loading IOLs into injectors and protection of the ocular surface during surgery

ProGel OV200 from Ophtec

Typical  2.0% HPMC, in a 2.0 ml Syringe and 23G Cannula. Low Viscosity with maximal Coating Effect  Dispersive, -23g Cannula

Pupil Expansion Type 5 S

semicircular elastic PMMA ring for the expansion of the pupil during phacoemulsification. Pupil Size 5.0-6.0 mm.

Use of the Geuder G 32970 Injector recommended by Morcher.

Video https://www.youtube.com/watch?v=GiQsOnPtutI

Video+ Instruments Akahoshi Full Set of instruments Asico (2014)

brilliant surgery tactics with right instrumentation

Diamond main Incision instrument AE 8190

Diamond 45 second incision AE 813

Capsulorhexis Forceps  for <2.2 …. AE-4347 (AE 4345-cross Action)

Hydrodissection Cannula AE 7636  NB: Chang’s is better AE 7638 (also 27G)

Prechopper -Hard AE-4190

Nucleus Stabilizer AE 2530

Prechopper -Soft AE 4192

Harmonyx -torsion all- phaco tip (Akahoshi 12degrees) Centurion

IOL Loader (Acrysof) AE 4253

Tutorial Video

https://www.youtube.com/watch?v=ux5rCIsa1oI