Showing 1–28 of 56 results

Amvisc Plus Viscoelastic

1,6% Sodium Hyaluronate (HA) in a 0,8ml sterile glass Syringe. Exhibits both cohesive and Dispersive properties and optical clarity for vesatile use during routine procedures from capsulorhexis to IOL placement.

ArtiVisc OVD from Ophtec

1% NaHA with >5 million Daltons Molecular Weight and high Viscosity: 1 million cPs Zero shear rate, in 0,55ml and 0,85ml syringe. 27G cannula.

ArtiVisc Plus OVD from Ophtec

1,4% NaHA with >5 million Daltons Molecular Weight and high Viscosity: 3.3 million cPs Zero shear rate, in 0,55ml and 0,85ml syringe. 25G cannula.

Bean Rings 80/80A/80B/80C/80D/80E/80F

Bean Segments are capsular supporting devices in 5 sizes 11-15mm used to offer additional capillary support and centration with the use of the BIL (Bag in the Lens) Project.

Video: https://www.youtube.com/watch?v=JOgf2mtSK0I

CataRhex 3 Phaco Unit (Oerli)

This interesting 3rd generation machine is excellent and specialized in performing sub 2.0 mm Cataract surgery for over 10 years. This  increadible 5kgr Device features:

1/ Efficient heavy duty Fragmentation- see 3.

2/ Fast rising Vacuum Peristaltic Pump with precise Flow Control, CortexMode:  in combination with proper inhouse designed instrumentation the SPEEPMode in removing residual lens material is supposed to be a clear advantage of this technology.

3/ Robust Phaco piece, light and effective with 6 piecoelectric elements a for sub 1.8mm incisions .

4/ affordable consumables.

5/ Ability to perform HF (high Frequency) semi automated capsulotomy (see Videos- Capsulotomy)

6/ HFDS ; High Frequency Deep Sclerectomy Feature, MIGS procedure from Oerli. Probably already obsolete.

 

Centurion Vision System (Alcon)

Centurion was launched by Alcon in 2013.  Since then it has easilty become the no 1 cataract emulsifier in the US.

Benefits:

1/Active Fluidics: employs “Pressurized” Fluidics thus Surgeon can set and maintain (as well as incisions are well constructed!)  target IOP throughout the procedure. Vs Gravitational Fluidics where the pressure is fixed. or there is a lag while elevating the pole of the BSS…. Eliminates the need to manually adjust the Fluid Pressure.

2/ INTREPID  Micro Coaxial System: This unique “bend” but “Balanced” Tip is cuppled with the unique 0.9mm Nanosleeve (at the Ozil IP Handpiece) featured in the latest Infinity. This tip is -of course-a must when using the machine since it reduces tip movement and leak at incision and greatly enhances tortional power.

3/ excellent interface of parameter adjustment to regulate flow and Efficiency at the Tip, if however the user is accustomed to the latest generation of Pulse/ Burst and Hyperpulse balance of the Infinity along with the new feature: the bimodal set of Vacuum and Asp Flow. Otherwise you can be intimidated if you try to take your first ride on the Centurion (which can be very disapointing!)

CETUS NANO-LASER (A.R.C LASER)

This 2nd Gen, 1064nm pulsed at 10Hz solid state  Laser Source , pulse duration 5nsec, is able to elicite  “cool-low energy” photodisruption of the lens in order to perform frank all Laser Cataract Surgery. The Single use probe is connected to the Cetus AND your Phaco machine for Aspiration/ Irrigation. Works well with the Alcon Units.

Constellation Vision System (Alcon)

NB

Even if marketed only as a posterior Segment unit, the Constellation with the Venturi pump and pressurized fluidics combined with Alcon’s superb newer Phaco handpiece with the nanosleeve, offers an excellent Phacoemulsifier at least as good if not better then the all time honored Infinity System.

DisCoVisc OVD/ Alcon

1.65% NaHA with 4% Chondroitin Sulfate, 1.65 Million Daltons Molecular Weight and medium/low Viscosity 75.000 cPs Zero shear rate, in 1.0ml syringe. 27G cannula. Classified by ALCON as Viscous Dispersive

DuoVisc OVD/ Alcon

Viscoat: Medium Viscosity Dispersive (Viscosity Zero Shear stress 40.000cps), 3% NaHA-4% Chondroitin Sulfate

ProVisc: Viscous Cohesive,  1% NaHA, 2.4million Dalton and Dynamic Viscosity 39.000 cps. Use during Capsulorhexis and IOL placement,

 

EVA Upgraded Phaco-Vitrectomy System (DORC)

EVA-upgrated features a sophisticated system of two pistons, two valves and three sensors to regulate flow to the eye with 3X faster rise time then a traditional Venturi System. This patented system “VACUFLOW VTi-Vslve Timing intelligence should eliminate post occlusion surge. EVA operates with a single universal cassette for anterior or posterior segment Surgery.

EYECRYL Lens for Phakic Eyes (Biotech)

Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm

Optic Size 4.65mm to 5.5mm according to dioptric correction

Range -3D to -23.0 D

EYECRYL Toric Lens for Phakic Eyes (Biotech)

Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm

Optic Size 4.65mm to 5.5mm according to dioptric correction

Range -3D to -23.0 D

Healon 5 Viscoelastic (J J)

4.000.000 mil Dalton MW, 2.3 % concentration, prototype of supercohesive with zero shear Viscosity of 7.000.000 mPas. 0.60ml Volume. The best to viscodilate the pupil.

 

Healon Duet Viscoelastic (J J)

Each Container has two OVDS

a/ Healon Endocoat : 800.000mil Dalton MW, 3 % concentration with zero shear Viscosity of  50.000 mPas.  0,85 ml Volume. Dispersive

b/ Healon Pro : 3,2 mill Dalton, 1% concentration, prototype of Viscoelastics with zero shear viscosity of 150.000mPas Cohesive  0,55ml

 

Healon GV Viscoelastic (J J)

5.000.000 mil Dalton MW, 1.4% concentration, prototype of supercohesive with zero shear Viscosity of 2.500.000 mPas. 0.55 and 0.85ml Volumes

 

Healon Pro Viscoelastic (J J)

3.200.000 mil Dalton MW, 1 % concentration, prototype of all viscoelastics. Cohesive  with zero shear Viscosity of 150.000 mPas. 0.55/ 0,80 ml Volume.

 

iLIGHT Speculum

Is an oblique light placed directly onto the lid speculum to facilitate Visability during Surgery

From www.surgilum.com