C-flex Aspheric 970C (Rayner)
Anterior Aspheric SA=0 5,75mm Optic in a 12.0 Hydrophilic Acrylic Lesn for in the Bag Fixation.
Showing 57–84 of 250 results
Anterior Aspheric SA=0 5,75mm Optic in a 12.0 Hydrophilic Acrylic Lesn for in the Bag Fixation.
Spheric 5,75mm Optic in a 12.0 Hydrophilic Acrylic
one piece hydrophilic IOL designed for in the bag/ alternative fixation (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for in the bag/ alternative fixation (Named after the two bumps on each haptic)
Toric model with Real Axis Technology (1-6 Dpt, Place IOL always 0-180, Astigmatism is custome-made with 1degree accuracy,
one piece hydrophilic IOL designed for add on use- Concave Convex Optic (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic with bifocal optics (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic to correct Sphere/ Astigmatism / Presbyopia +3.0 Spectacle Plane (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic to correct Sphere/ Astigmatism (Named after the two bumps on each haptic)
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
Hydrophilic Acrylic for < 2.20mm incision Surgery, with Spherical Surface f, extended Range in myopia, from France and IOLART (GR/CY)
Hydrophilic Acrylic for < 2.20mm incision Surgery, with Aspherical posterior Surface (Aberration Neutral), from France and IOLART (GR/CY)
Based on the Crystalens Platform -Embedded Polymide haptics into the hinged Silicone Plate of the IOL. with Aspheric Optics. B+L will supply AO1UV (11,5mm) and AO2UV (12,0) for smaller/hyperopic and larger/myopic eyes respectively (From +17 0 to +27.0 in 0,25D steps!)
Preloaded plate Hydrophilic Implant with negative Spherical Aberration Contol. (SA negative) MP _ preloaded
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive/diffractive technology offering +3.50D Add (IOL Plane). For capsular bag fixation. DOLA Technology: Diffractive Optic Local Asphericity –DOLA– meant to reduce Halo/ Dysphotopic Burden of Bifocal IOLs.
yellow tinted hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)
EDEN: Proprietary EDOF technology that excibits a unique exagerrated aspheric (central region 1mm- Instant Focus Technology), combined with a diffractive Zone (3.5mm) and Refractive (to 6mm) properties. One piece Hydrophilic acrylic with double closed loops IOL in two Sizes.
Hydrophobic Glistening Free IOL for incisions >2,2mm (BLIS Injection system)
Hydrophobic Glistening Free IOL with a posterior Toric Surface, for incisions >2,2mm (BLIS Injection system)
one piece hydrophilic IOL with EDOF undisclosed Refractive Technology , 4 point fixation -4 closed loops-.
Toric Customized Model has according to diopter possibility to correct astigmatism up to 15D in 0,25D steps.
NB : An AAO Task Force consensus statement requires EDOF IOLs to be within one line of BCVA of monofocal IOLs; to have 0.5D more of defocus than a monofocal at 20/30 level (therefore, approximately 1.25D defocus), and 50% patients to be better than 20/30.
one piece hydrophilic IOL with EDOF undisclosed Refractive Technology , 4 point fixation -4 closed loops-.
“The innovative technology and unique optics of the EyeMax lens diverts images away from the damaged part of the eye and enhances them to the healthy parts, leading to a significant improvement of vision for patients. The shape of the Eyemax Lens redirects the same high quality image at every point of the retina, leaving the selection of the best alternative macula to the human brain.” -so called “Proprietary Hyper-Wavefront Modified Optics by Optical Physist P Artal. Concept by Dr B Qureshi.
The Lens is combined with high + Specs to produce magnification.
Refractive Target +3D : 10% Mag, +6D 20% mag (+10 to 30%)
To obtain IOL visit www.londoneyehospitalpharma.com
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
EDOF adding +1,50D bisegmented design, one piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm. Femto Capsulorhexis “ready” IOL
One piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm.
Hydrophilic monofocal one Piece IOL with aspheric Optics
4-point support Hydrophilic monofocal one Piece IOL with aspheric Optics 6/11 optic-overall length