FIL 65 PVS IOL Review Premium multifocal(Soleko)
one piece hydrophilic IOL with Soleco’s 4 small diameter refractive central zone (trifocal) , designed for kids/ bag/ sulcus and sclera fixation.
Showing 85–112 of 167 results
one piece hydrophilic IOL with Soleco’s 4 small diameter refractive central zone (trifocal) , designed for kids/ bag/ sulcus and sclera fixation.
one piece hydrophobic IOL with 4 point fixation -4 closed loops.
one piece hydrophobic IOL with 4 point fixation -4 closed loops -Preloaded .
one piece hydrophobic IOL with traditional design.
bifocal l IOL from Germany (i-Medical Heidelberg) with diffractive +3.00 OR +3.5D OR +4.00 near, in Hydrophilic, Plate -p model or modified closed C-loops -r model-
trifocal IOL from Germany (i-Medical Heidelberg) with diffractive +1,8D intermediate and +3.5D near, in Hydrophilic, Plate Configuration.
The Principle of the Accufocus intracorneal Implant -Kamra- realized in standard IOL technology
May be also appropriate for use in cases with corneal related macro aberrations
The “pinhole principle” is meant to increase depth of focus to about 3D. It has a non-diffractive 3.23mm diameter opaque PVDF mask with 1.36mm central aperture.
(NB Discuss possibility of Pulfrich Effect because of Dissimilar Intensity of Light between lights -consider dilating one eye only during consultation)
The IOL K features a centrally located high negative powered portion (1.7mm) covering the central scotoma but not interfearing with the rest of the optical Zone thus -according to the company- not affecting the patients mobility so much. With High powered Positive Specs the Patients enjoys a mag to 3x from the combination of the negative powered central portion of the IOL and the Hyperopic Specs (Gallilean Telescope)
Gallilean Type of Telescope: This Old-fashioned approach offers magnification through combination of a large + lens (up to +100D) placed in the bag and a strong meniscus minus AC Implant. Made from Lenspecial -Milano, Italy. (PMMA)
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D”
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D. This model corrects presbyopia adding “up to 4.0D” and astigmatism up to +10.0 D.
on line Calculator http:/www.ipciol.com/calc
Hydrophilic six haptic IOL to be placed in the sulcus of the phakic Eye. With central and peripheral ventilation holes. Central hole is 380μ. Incision <2.8mm. Optic Size is huge: 6.60 up to 7.5 possible Customized. Length from 11.00 to 14.00 in 0,25mm steps. Range -30.0 D to +15.0D
on line Calculator http:/www.ipciol.com/calc