Camellens FIL 622-2 PV Multifocal IOL (Soleko)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic with bifocal optics (Named after the two bumps on each haptic)
Showing 57–84 of 155 results
one piece hydrophilic IOL designed for add on use- Concave Convex Optic with bifocal optics (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic to correct Sphere/ Astigmatism / Presbyopia +3.0 Spectacle Plane (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic to correct Sphere/ Astigmatism (Named after the two bumps on each haptic)
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
one piece hydrophilic IOL with EDOF undisclosed Refractive Technology , 4 point fixation -4 closed loops-.
Toric Customized Model has according to diopter possibility to correct astigmatism up to 15D in 0,25D steps.
NB : An AAO Task Force consensus statement requires EDOF IOLs to be within one line of BCVA of monofocal IOLs; to have 0.5D more of defocus than a monofocal at 20/30 level (therefore, approximately 1.25D defocus), and 50% patients to be better than 20/30.
one piece hydrophilic IOL with EDOF undisclosed Refractive Technology , 4 point fixation -4 closed loops-.
“The innovative technology and unique optics of the EyeMax lens diverts images away from the damaged part of the eye and enhances them to the healthy parts, leading to a significant improvement of vision for patients. The shape of the Eyemax Lens redirects the same high quality image at every point of the retina, leaving the selection of the best alternative macula to the human brain.” -so called “Proprietary Hyper-Wavefront Modified Optics by Optical Physist P Artal. Concept by Dr B Qureshi.
The Lens is combined with high + Specs to produce magnification.
Refractive Target +3D : 10% Mag, +6D 20% mag (+10 to 30%)
To obtain IOL visit www.londoneyehospitalpharma.com
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
Hydrophilic monofocal one Piece IOL with aspheric Optics
4-point support Hydrophilic monofocal one Piece IOL with aspheric Optics 6/11 optic-overall length
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Toric Customized Hydrophylic one Piece IOL. Axis of IOL to implanted always at 0-180.
Toric Customized Hydrophylic Multifocal Lens (customized sphere/ astigmatism) 0,25D steps. 4 concentric refractive rings!
Hydrophilic monofocal one Piece IOL with aspheric Optics for in the bag/ sulcus and sclera fixation through sutures
Hydrophilic monofocal one Piece IOL with aspheric Optics 6/13 optic-overall length
one piece hydrophilic IOL where the Optical Element is connected to the Supporting Annulus through a Helix to theoretically allowe pivoting of the optic.
one piece hydrophilic IOL with Soleco’s 4 small diameter refractive central zone (trifocal) , designed for kids/ bag/ sulcus and sclera fixation.
one piece hydrophobic IOL with 4 point fixation -4 closed loops.
one piece hydrophobic IOL with 4 point fixation -4 closed loops -Preloaded .
one piece hydrophobic IOL with traditional design.
bifocal l IOL from Germany (i-Medical Heidelberg) with diffractive +3.00 OR +3.5D OR +4.00 near, in Hydrophilic, Plate -p model or modified closed C-loops -r model-
trifocal IOL from Germany (i-Medical Heidelberg) with diffractive +1,8D intermediate and +3.5D near, in Hydrophilic, Plate Configuration.
Gallilean Type of Micro-Telescope implanted also with inserter through a small corneosclera incision of 3mm (Tsert CI -Inserter- 2nd Image)
www.visioncareinc.net
The Principle of the Accufocus intracorneal Implant -Kamra- realized in standard IOL technology
May be also appropriate for use in cases with corneal related macro aberrations
The “pinhole principle” is meant to increase depth of focus to about 3D. It has a non-diffractive 3.23mm diameter opaque PVDF mask with 1.36mm central aperture.
(NB Discuss possibility of Pulfrich Effect because of Dissimilar Intensity of Light between lights -consider dilating one eye only during consultation)