Showing 57–84 of 155 results

CB144 UV2 PMMA IOL (Omni Lens)

one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation

CB144 UV2 PMMA IOL (Omni Lens)

one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation

EVOLVE EDOF Customized Toric Hydrophilic (Soleko)

one piece hydrophilic  IOL with EDOF undisclosed Refractive  Technology , 4 point fixation -4 closed loops-.

Toric Customized Model has according to diopter possibility to correct astigmatism up to 15D in 0,25D steps.

NB : An AAO Task Force consensus statement requires EDOF IOLs to be within one line of BCVA of monofocal IOLs; to have 0.5D more of defocus than a monofocal at 20/30 level (therefore, approximately 1.25D defocus), and 50% patients to be better than 20/30.

Eye Max Mono for AMD (Care Group)

“The innovative technology and unique optics of the EyeMax lens diverts images away from the damaged part of the eye and enhances them to the healthy parts, leading to a significant improvement of vision for patients. The shape of the Eyemax Lens redirects the same high quality image at every point of the retina, leaving the selection of the best alternative macula to the human brain.” -so called “Proprietary Hyper-Wavefront Modified Optics by Optical Physist P Artal. Concept by Dr B Qureshi.

The Lens is combined with high + Specs to produce magnification.

Refractive Target +3D : 10% Mag,   +6D  20% mag (+10 to 30%)

To obtain IOL visit www.londoneyehospitalpharma.com

EYECRYL Lens for Phakic Eyes (Biotech)

Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm

Optic Size 4.65mm to 5.5mm according to dioptric correction

Range -3D to -23.0 D

EYECRYL Toric Lens for Phakic Eyes (Biotech)

Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm

Optic Size 4.65mm to 5.5mm according to dioptric correction

Range -3D to -23.0 D

IOL Expert IC-8

The Principle of the Accufocus intracorneal Implant -Kamra- realized in standard IOL technology

May be also appropriate for use in cases with corneal related macro aberrations

The “pinhole principle”  is meant to increase depth of focus to about 3D. It has a non-diffractive 3.23mm diameter opaque PVDF mask with 1.36mm central aperture.

(NB Discuss possibility of Pulfrich Effect because of Dissimilar Intensity of Light between lights -consider dilating one eye only during consultation)