not applicable

Showing 57–84 of 153 results

Lentis L-313 -Oculentis

One piece hydrophilic plate Acrylic lens and Biaspherical Optics for capsular bag fixation

Lentis L-313Y -Oculentis

One piece hydrophilic plate Acrylic lens and Biaspherical Optics for capsular bag fixationexhibits extra UV protection in violet light

Lentis L-323 -Oculentis

One piece hydrophilic plate Acrylic lens and Biaspherical Optics compensating Cornea Asphericity for capsular bag fixation

Lentis LS-312Y -Oculentis

One piece hydrophilic Acrylic lens with modified C loop Haptics and Biaspherical Optics for capsular bag fixationwith UV absorbing additional violet light filter

Lentis LS-313-MF15 -Oculentis

One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +1.5 Add and real Extended Dioptric Range

Lentis LU-814 VR -Oculentis

One piece hydrophilic Acrylic lens with 4 open loop haptics with aspherical surface fror Capsular, sulcus and Sulcus-Sclera fixation. Enlarged Haptics for possible Suture Fixation

Lentis Mplus LS-313-MF20 -Oculentis

One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +2.0 Add

Note that only +3.0 Add is offered with a surface Optimizatuion for Paraxial Optics (MpusX)

Lentis Mplus LS-313-MF30/ Lentis MplusX LS-313 MF30 -Oculentis

One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add

There is an older Version Mplus and a newer MpusX offering better paraxial optics (Additive Paraxial Asphericity) and “Surface Design Optimisation”. Note that this X is currently only available with the +3.0 segmented Optic

Lentis-LU 814 MF30 -Oculentis

One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add that may be placed in the eye in cases of inadequate capsular support

LUCIDIS Swiss Advanced Vision

LUCIDIS:  Proprietary EDOF technology that excibits a unique exagerrated aspheric (central region 1mm- Instant Focus Technology) combined with monofocal (prob Aspheric) Refractive (to 6mm) properties.  One piece Hydrophilic acrylic with double closed loops IOL in two Sizes.

LUCIS (Cristalens)

Hydrophilic Acrylic for <2.00mm incision Surgery, with posterior Surface Aspheric SA-neutral, from France and IOLART (GR/CY)

M-flex 580F/ 630F (Rayner)

Bifocal Lens adding +3.0 OR +4.0 at IOL plane, with 5,75mm (580F) or 6.25mm (630F) optical Zone.  +3.00 Add offered from +14.0D to 30.0D Range (0,5D increments) and +4.00 Add offered from +10.0 D to +30.0D

MC X11 ASP -Monofocal HumanOptics (Copy)

One piece  hydrophilic Acrylic plate  lens,  aspherical Optics  and optical Zone from 5,5 to 7.0 according to dioptic correction required . For capsular bag fixation.

Monomax PC 550

One Piece hydrophilic acrylic IOL with 2   Mod. C loops (Acrysof -like).

OPTIFLEX TRIO -Biotech

Hydrophobic Acrylic containing Natural Chromophore Trifocal Aspheric IOL with nominal light distribution 45% distance, 27% intermediate (+1.85D) and 28% near (+3.50D)

Partial Aniridia Implant Type 67D Morcher

total Diameter 13.5 mm.  Requires fair incision of >7.0 mm.  Pupillary Aperture 3.5 mm. With positioning holes for intrasleral fixation through sutures (9-0 Prolene on Spatula needle)

Partial Aniridia Implant Type 67E Morcher

total IOL Diame ter 13.5 mm. Requires fair incision of >8.0 mm.  Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation. (9-0 Prolene-spatula Needle)

Partial Aniridia Implant Type 68C Morcher

total IOL Diameter 14.00  mm. Requires fair incision of >7.0 mm.  Pupillary Aperture 3.5 mm. Two positioning holes in each haptic for suture to sclera fixation.

Partial Aniridia Implant Type 94C Morcher

total IOL Diame ter 13.5.00  mm. Requires fair incision of >8.0 mm.  Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation.