M-flex T 588F/ 638F (Rayner)
Bifocal Lens adding +3.0 OR +4.0 at IOL plane, with 5,75mm (580F) or 6.25mm (630F) optical Zone. +3.00 Add offered from +14.0D to 30.0D Range (0,5D increments) and +4.00 Add offered from +10.0 D to +30.0D
Showing 29–53 of 53 results
Bifocal Lens adding +3.0 OR +4.0 at IOL plane, with 5,75mm (580F) or 6.25mm (630F) optical Zone. +3.00 Add offered from +14.0D to 30.0D Range (0,5D increments) and +4.00 Add offered from +10.0 D to +30.0D
Hydrophobic Acrylic containing Natural Chromophore Trifocal Aspheric IOL with nominal light distribution 45% distance, 27% intermediate (+1.85D) and 28% near (+3.50D)
Preloaded Hydrophilic (Rayacryl-26% H2O) IOL with Anterior Aberration Neutral Optics. Extended Range from high Hyperopia (34D) to Extreme Myopia (-10D).
ADD ON Hydrophilic Acrylic IOL for for < 2.20mm incision Surgery, with spherical Optics, Ventilating holes, from France and IOLART (GR/CY)
S
one piece Hydrophilic acrylic ( Hybrid Acrylic) with 2 closed loop design offering diffractive -apodized designed IOL with a nominal Add of +3.5D IOL Plane (2,8D Spectacle plane)
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Add +3,5D at IOL plane.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Bifocal Add +3,5D at IOL plane.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Trfocal Add +1.75D and 3,5D at IOL plane.
Bifocal IOL on TECNIS Platform , pior aspheric surface and posterior diffractive optics. Add of +2.75 IOL plane (+2.01D spectacle plane)
Bifocal IOL on TECNIS Platform , pior aspheric surface and posterior diffractive optics. Add of +3.25 IOL plane (+2.37D spectacle plane)
Bifocal IOL on TECNIS Platform , pior aspheric surface and posterior diffractive optics. Add of +4.00 IOL plane (+3.0 D spectacle plane)
EDOF IOL on TECNIS Platform , posterior achromatic diffractive surface designed to reduce chromatic aberrations for enhanced image contrast, “echelette: feature to extend the range of vision.
EDOF IOL on TECNIS Platform , posterior achromatic diffractive surface designed to reduce chromatic aberrations for enhanced image contrast, “echelette: feature to extend the range of vision. Toric Correction from 1.50 to 3.75D (4 models) IOL Plane
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive technology. For capsular bag fixation. Infinite Spherical/ Astigmatism Correctiuon -20D to +40D and astigmatism +1D to +20D
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive/diffractive technology offering +3.50D Add (IOL Plane). For capsular bag fixation. DOLA Technology: Diffractive Optic Local Asphericity –DOLA– meant to reduce Halo/ Dysphotopic Burden of Bifocal IOLs. Astigmatism Correctiuon +1D to +6.0 D IOL Plane.
Hydrophilic Add On Trifocal IOL from 11.00 to +14.00mm with 6,2mm Optic Diameter. Vault Height 0.00mm. Adds +1.8D intermediate and +3.5D for near.
Hydrophilic Add On Trifocal IOL from 11.00 to +14.00mm with 6,2mm Optic Diameter. Vault Height 0.00mm. Adds +1.8D intermediate and +3.5D for near. This model can correct astigmatism from +0,5 D to +10.0 D.
Yellow Hydrophilic Plate Aspheric Bifocal IOL for Astigmatism Control.
Wichterle (Continouos Focus) IOL is an innovative IOL without Haptics made from a 8.9mm Bioanalogic Hydrogel with a number of proprietary characteristcs like negative spherical aberrations providing by its smooth hyperbolic curve, an infinite number of focal points that extend the depth of focus, The Refractive power is maximal in the center and continuously decreases without steps to the periphery,
Diffractive, bitoric aspheric (aberration Neutral) Hydrophilic Acrylic, Depth of Focus Extending by 0,95D and 1,90D. MP _ preloaded
Diffractive, aspheric (aberration correcting) Hydrophilic Acrylic, Depth of Focus Extending by 0,95D and 1,90D. MP _ preloaded (BLUEMIXS 180)
Bifocal, Diffractive, aspheric (aberration correcting) Hydrophilic Acrylic, Near Add at IOL plane +3.75D MP _ preloaded
Bifocal, Diffractive, toric aspheric (aberration correcting) Hydrophilic Acrylic, Near Add at IOL plane +3.75D MP _ preloaded
Trifocal, Diffractive, toric aspheric (aberration correcting) Hydrophilic Acrylic, Intermediate Add +1.66D , Near Add at IOL plane +3.33D – IOL Plane. Preloaded only