Partial Aniridia Implant Type 94 Morcher
total Diameter 13.5 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0 mm. Not for sclera fixation through sutures!
Showing 29–53 of 53 results
total Diameter 13.5 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0 mm. Not for sclera fixation through sutures!
total IOL Diame ter 13.5.00 mm. Requires fair incision of >8.0 mm. Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation.
All the Available PMMA Models from Alcon for Use in the Anterior Chamber. All require large incisions (5.7mm). MUST Follow Sizing Guidance ! 6 Models Available ….
For detailed description visit the site
https://www.myalconstore.com/education-resources/surgical-product-information/
Six Old Fashioned PMMA IOLs Models from Alcon requiring large incisions. For Reference and special cases only.
ADD ON Hydrophilic Acrylic IOL for for < 2.20mm incision Surgery, with spherical Optics, Ventilating holes, from France and IOLART (GR/CY)
S
Peculiar looking suturefree IOL for Fixation under scleral flaps throygh Trascleral plugs. Customized optic to provide toricity control at 0,25D steps! Injector: Medical Viscojet 2.2 or 2.7 . As per Company 2 week delivery time.
Watch the video!
Peculiar looking suturefree IOL for Fixation 23G.
Watch the video!
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia in pseudophakia. The IOL is supplied with a Rayner Injector.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Add +3,5D at IOL plane.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Bifocal Add +3,5D at IOL plane.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia (Sphere and astigmatism) in pseudophakia. The IOL is supplied with a Rayner Injector for incisions <2.7mm.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Trfocal Add +1.75D and 3,5D at IOL plane.
One piece hydrophilic Acrylic lens with modified C loop Haptics and aspheric Optics Available also in Yellow Tint (812Y) Extended Dioptic Range to Hyperopia (+42D) and large Optic (6,5mm)
one piece PMMA lens (12.0 mm) with 6.5 mm Optic. Primary for in the Bag Fixation/ Open Sky Approach. Better Options Offered for Sulcus Fixation
one piece PMMA lens (13.0 mm) with 6.5 mm Optic. Primary for in the Bag Fixation/ Open Sky Approach. Better Options Offered for Sulcus Fixation
one piece PMMA lens (13.0 mm) with 7.0 mm Optic. Primary for in the Bag Fixation/ Open Sky Approach. Better Options Offered for Sulcus Fixation
one piece Hydrophilic Acrylic lens (13.0 mm) with 6.5mm Optic. With Positioning holes for sclera fixation (9-0 Prolene CTC-6L Ultima SPATULA)
one piece PMMA lens (14,2 mm) with 6.5 mm Optic. Modified C- “J” Loop design. Primary for in the Bag Fixation/ Open Sky Approach in Extreme Myopia. Up to -10.0D Better Options Offered for Sulcus Fixation
one piece PMMA lens (14,2 mm) with 6.5 mm Optic. C- Loop design. Primary for in the Bag Fixation/ Open Sky Approach in Extreme Myopia. Up to -10.0D Better Options Offered for Sulcus Fixation
one piece PMMA lens (13.5 mm) with 6.5mm Optic and 3 positioning holes for sclera fixation per haptic. (9-0 Prolene CTC-6L Ultima SPATULA)
one piece PMMA lens (13.0 mm) with 7.0 mm Optic. Primary for in the Bag Fixation/ Sulcus for Open Sky Approach.
one piece Hydrophilic Acrylic lens (15.0 mm) with 6.5mm Optic. With Positioning holes for sclera fixation (9-0 Prolene CTC-6L Ultima SPATULA)
one piece hydrophilic Acrylic lens with large C-loop Haptics and large Optic of 6.5mm, For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
one piece hydrophilic Acrylic lens with 4 closed loop haptics for bag fixation only. Overall Length 10,5mm-11.0mm. Optic Diameter 5,5mm to 6.5mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
Wichterle (Continouos Focus) IOL is an innovative IOL without Haptics made from a 8.9mm Bioanalogic Hydrogel with a number of proprietary characteristcs like negative spherical aberrations providing by its smooth hyperbolic curve, an infinite number of focal points that extend the depth of focus, The Refractive power is maximal in the center and continuously decreases without steps to the periphery,