311 Aniridia Implant (Ophtec)
https://www.youtube.com/watch?time_continue=29&v=KJ-7u2QWqw4
IOL-Iris Composite device with 4mm optic. Requires a big wound, We do not advice utilizing anything but black!
Showing all 22 results
https://www.youtube.com/watch?time_continue=29&v=KJ-7u2QWqw4
IOL-Iris Composite device with 4mm optic. Requires a big wound, We do not advice utilizing anything but black!
one piece PMMA Kelman type of IOL from Soleko.
Iris fixated IOL from India. From the Care Group.
Iris fixated IOL designed for a spherical correction in cases of inefficient capsular Support.
In our opinion it is primarily a posterior Chamber Lens (A*=116.8) that may be enclavated in the Anterior Chamber if needed (A*=115,7) Note that the aphakic and less expensive Version is Biconvex (Only +2D to +9.0 are plano-Convex)
*Optical
PMMA Iris Fixated IOL for correction of Hyperopia.
NB: we no longer recommend the use of this lens in phakic eyes
Iris fixated PMMA IOL for myopia correction in Phakic Eyes. A preferred choice for most patients.
Iris fixated IOL designed for a spherical and cylindrical correction of myopic and hyperopic eyes.
N.B. The site does NOT recommend the use of this lens in Hyperopic Phakic Eyes.
one piece hydrophilic IOL designed for add on use- Concave Convex Optic (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic with bifocal optics (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic to correct Sphere/ Astigmatism / Presbyopia +3.0 Spectacle Plane (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic to correct Sphere/ Astigmatism (Named after the two bumps on each haptic)
Based on the Crystalens Platform -Embedded Polymide haptics into the hinged Silicone Plate of the IOL. with Aspheric Optics. B+L will supply AO1UV (11,5mm) and AO2UV (12,0) for smaller/hyperopic and larger/myopic eyes respectively (From +17 0 to +27.0 in 0,25D steps!)
ADD ON Hydrophilic Acrylic IOL for for < 2.20mm incision Surgery, with spherical Optics, Ventilating holes, from France and IOLART (GR/CY)
S
Peculiar looking suturefree IOL for Fixation under scleral flaps throygh Trascleral plugs. Customized optic to provide toricity control at 0,25D steps! Injector: Medical Viscojet 2.2 or 2.7 . As per Company 2 week delivery time.
Watch the video!
Peculiar looking suturefree IOL for Fixation 23G.
Watch the video!
Based on the Crystalens Platform -Embedded Polymide haptics into the hinged Silicone Plate of the IOL. B+L will supply AT50T (Spheric Toric Optics) or aspheric Optics (BL1UT) This Lens has better UV coverage then previous model (BL1AT)
Iris fixated PMMA IOL for myopia correction in Phakic Eyes from -5.0 to -20.0 D.
Iris fixated IOL designed for use in phakic Eyes. In our opinion the 5.00 OZ is more versatile and preferred in myopia without significant astigmatism.
is the Opthec Artisan 204 (6mm Optic) marketed by J&J as Verisyse
Wichterle (Continouos Focus) IOL is an innovative IOL without Haptics made from a 8.9mm Bioanalogic Hydrogel with a number of proprietary characteristcs like negative spherical aberrations providing by its smooth hyperbolic curve, an infinite number of focal points that extend the depth of focus, The Refractive power is maximal in the center and continuously decreases without steps to the periphery,