Scleral Suturefree IOL Carlevale FIL SSF TORIC (Soleko)

Peculiar looking suturefree IOL for Fixation under scleral flaps throygh Trascleral plugs. Customized optic to provide toricity control at 0,25D steps! Injector: Medical Viscojet 2.2 or 2.7 . As per Company 2 week delivery time.

Watch the video!

Sulcoflex Aspheric IOL 700L (Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia in pseudophakia. The IOL is supplied with a Rayner Injector.

Sulcoflex Multifocal IOL 653F(Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision).  Add +3,5D at IOL plane.

Sulcoflex Multifocal Toric IOL 653F (Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Bifocal Add +3,5D at IOL plane.

Sulcoflex Toric IOL 710LT (Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia (Sphere and astigmatism) in pseudophakia. The IOL is supplied with a Rayner Injector for incisions <2.7mm.

Sulcoflex Trifocal IOL 703F (Rayner)

Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Trfocal Add +1.75D and 3,5D at IOL plane.

Tek-Lens II Model 612/ 612Y (TEKIA)

3-piece IOL with Full C Haptics (Longer then 611) and Round anterior Edge, Haptic Angulation 5 degrees. Still hardly Adequate for alternative Fixation in the sclera (12.5mm)

Tek-Lens II Model 613/ 613Y (TEKIA)

3-piece IOL with Full C Haptics and Round anterior Edge, Haptic Angulation 5 degrees and 13mm overall diameter therefore adequate for intrascleral Fixation

Tek-Lens II Model 616/ 616Y (TEKIA)

3-piece IOL with Full C Haptics and Round anterior Edge, Haptic Angulation 5 degrees and 13mm overall diameter therefore adequate for intrascleral Fixation

Trulign Toric IOL (model BL1UT)) Bausch+Lomb

Based on the Crystalens Platform -Embedded Polymide haptics into the hinged Silicone Plate of the IOL. B+L will supply AT50T (Spheric Toric  Optics) or aspheric Optics  (BL1UT) This Lens has better UV coverage then previous model (BL1AT)

Type 89A TORIC “Bag in Lens -Tassignon” -Morcher

one piece hydrophilic  Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon  needs dedication and proficiency performing PCCC -the “right” way. This Version corrects Astigmatism up to +8,00D.

 

type 92 G Monofocal Hydrophilic Morcher

one piece hydrophilic  Acrylic lens with large C-loop  Haptics and large Optic of 6.5mm,  For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6