Peculiar looking suturefree IOL for Fixation under scleral flaps throygh Trascleral plugs. Customized optic to provide toricity control at 0,25D steps! Injector: Medical Viscojet 2.2 or 2.7 . As per Company 2 week delivery time.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia in pseudophakia. The IOL is supplied with a Rayner Injector.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Add +3,5D at IOL plane.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Bifocal Add +3,5D at IOL plane.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia (Sphere and astigmatism) in pseudophakia. The IOL is supplied with a Rayner Injector for incisions <2.7mm.
Hydrophilic Acrylic one piece Lens with large Optic and 14mm overall diameter specially designed for Sulcus placemnet (Undulating and rounded C-looped haptics) 10 degree posteriorly vaulted Optic to correct residual ametropia/ Presbyopia in pseudophakia. The IOL is supplied with a Rayner Injector (2,2mm incision). Trfocal Add +1.75D and 3,5D at IOL plane.
3-piece IOL with Full C Haptics (Longer then 611) and Round anterior Edge, Haptic Angulation 5 degrees. Still hardly Adequate for alternative Fixation in the sclera (12.5mm)
3-piece IOL with Full C Haptics and Round anterior Edge, Haptic Angulation 5 degrees and 13mm overall diameter therefore adequate for intrascleral Fixation
3-piece IOL with Full C Haptics and Round anterior Edge, Haptic Angulation 5 degrees and 13mm overall diameter therefore adequate for intrascleral Fixation
Based on the Crystalens Platform -Embedded Polymide haptics into the hinged Silicone Plate of the IOL. B+L will supply AT50T (Spheric Toric Optics) or aspheric Optics (BL1UT) This Lens has better UV coverage then previous model (BL1AT)
one piece hydrophilic Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon needs dedication and proficiency performing PCCC -the “right” way. This Version corrects Astigmatism up to +8,00D.
one piece hydrophilic Acrylic lens with large C-loop Haptics and large Optic of 6.5mm, For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6