>1.8mm

Showing 1–28 of 36 results

Akreos AO60 (Bausch + Lomb)

Specialized Lens for MICS incisions less then 2.2 mm. Available in 10,5mm (for hyperopic) 10,7mm (Emmetropic) & 11.00mm (Myopic Eyes) sizes according to corresponding Power of the IOL.  Low index of refraction is supposed to limit Reflections from the IOL.. (As Adapt the Optic is Spheric- as AO it is  aspheric)

Akreos MICS M160L IOL (Bausch + Lomb)

Specialized Lens for MICS incisions less then 2.2 mm. Available in 10,5mm (for hyperopic) 10,7mm (Emmetropic) & 11.00mm (Myopic Eyes) sizes according to corresponding Power of the IOL.  Optic Zone is from 6,2mm in low Powered Lenses to 5.6mm in high powered Lenses  ( >22.0 D!)  Low index of refraction is supposed to limit Reflections from the IOL.

Alsafit Fourier Trifocal (Alsanza)

total presbyopia correcting, one piece IOL (TRIFOCAL IOL) with alleged impressive light transmission 91.4%.

material: smart matrix, interpenetrating polymer network of hydrophobic and hydrophilic acrylic

haptic design features : 4 suspensive corner fins, 2 wide OVD aspiration holes, 4 positioning holes

Addition: +3.55D at 35cm , +1.77 D at 70cm

Company claims their design with  “Fourier” Designed “reverse Apodization” will improve 24h light distribution and Dysphotopic symptoms. -Height of harmonic waves (no diffractive steps) INCREASE from center to periphery!

AS-6D iDIFF Plus -yellow tinted hydrophilic- IOL R Cloop or P Plate -(Care Group)

“iDIFF Plus is a newer generation refractive-diffractive presbyopic IOL with an increasing step height diffractive pattern combined with increased step angulation between transition zones, resulting in superior optical quality for both distance and near. The design enables balanced distribution of light (60/40 light distribution for far and near respectively) and higher MTF values, which increases contrast sensitivity in all lighting conditions and reduces the effects of scattered light, such as persistent glare and haloes and is pupil independent.” copied from website.

Comes as iDiff R (C-loop haptics)  and iDiff P (plate) in 3 Adds +4.00/ +3.50/ +3.00 

CT ASPHINA 409M/MP

Preloaded plate Hydrophilic Implant with Spherical Aberration Contol. (Aspherisity Neutral)

CT ASPHINA 509M/MP

Preloaded plate Hydrophilic Implant with negative Spherical Aberration Contol. (SA negative) MP _ preloaded

CT Spheris 204

Spheric Plate,  hydrophilic with “hydrophobic” surface IOL available in extended dioptic Range.

Tek-Lens II Model 820/ 820Y (TEKIA)

One piece hydrophilic Acrylic lens with four modified closed  loop Haptics and aspheric Optics Available also in Yellow Tint (820Y) Extended Dioptic Range to Hyperopia (+42D)

Tek-Lens II Model 860/ 860Y (TEKIA)

One piece hydrophilic Acrylic plate lens with  aspheric Optics Available also in Yellow Tint (860Y) Extended Dioptic Range to Hyperopia (+42D)

Tek-Lens II Model 870/ 870Y (TEKIA)

One piece hydrophilic Acrylic lens with modified C loops Haptics ,  aspheric Optics Available also in Yellow Tint (870Y) Extended Dioptic Range to Hyperopia (+42D)

Tek-Tor Model 820 / 820Y

One piece with 4-modified closed loop Haptics IOL from Hydrophilic Acrylic for Astigmatism Correction +1.50D/ +2.25D / +3.0D at IOL plane.