PMMA

Showing 1–28 of 54 results

AcrySof MA60 MA/ MN60 MA

White (MA) or Yellow spherical Optic, 3-piece IOL for LOW POWERS (-5.0D to +5.0D)only.  Also for Alternative Fixation Sulcus/Sclera/ Iris

Aniridia Implant Type 67G Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 5.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle. Also without Optic Available.

NB Intraop support of the IOL with Long Prolene Needle (Dr Sundmacher et al) https://www.youtube.com/watch?v=ucrk-EVDdMU

Aniridia Implant Type 67L Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 3.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle Opening in the diaphragm inferiorly for the injection of Vitreous Fluid Substitutes/ inferior iridotomy for silicone oil.

Aniridia Implant Type 68 Morcher

Requires huge incision of >10.0mm. Pupillary Aperture 4.5 mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle

Artisan Aphakia Model 205 (Ophtec)

Iris fixated IOL designed for a spherical correction in cases of inefficient capsular Support.

In our opinion it is primarily a posterior Chamber Lens (A*=116.8) that may be enclavated in the Anterior Chamber if needed (A*=115,7) Note that the aphakic and less expensive Version is Biconvex (Only +2D to +9.0 are plano-Convex)

*Optical

Artisan Myopia Model 206

Iris fixated PMMA IOL for myopia correction in Phakic Eyes. A preferred choice for most patients.

Artisan Toric Iris Fixated IOL (Ophtec)

Iris fixated IOL designed for a spherical and cylindrical correction of myopic and hyperopic eyes.

N.B. The site does NOT recommend the use of this lens in Hyperopic Phakic Eyes.

Nulens Dynacurve IOL (Nulens ltd)

The NuLens Dynacurve accommodative IOL (NuLens, Ltd., Herzliya Pituah, Israel) consists of: 1) polymethyl methacrylate (PMMA) haptics that are designed to be placed in the ciliary sulcus; 2) a PMMA anterior reference plane that provides distance vision correction; 3) a small chamber containing a solid silicone gel and 4) a posterior piston with an aperture in the center.

Such IOL prototypes, even with silicone gel of a relatively low refractive index (1.40), have been shown in a primate eye to deliver more than 40.00 D of accommodation using only 500 µm of vertical diaphragm displacement. No wonder the principle was evaluated clinically in AMD Patients, providing additional evidence regarding the Concept of possible extreme Accommodation. This Prototype of lens required a 9mm incision to be inserted in the sulcus/bag.

 

Partial Aniridia Implant Type 67D Morcher

total Diameter 13.5 mm.  Requires fair incision of >7.0 mm.  Pupillary Aperture 3.5 mm. With positioning holes for intrasleral fixation through sutures (9-0 Prolene on Spatula needle)

Partial Aniridia Implant Type 67E Morcher

total IOL Diame ter 13.5 mm. Requires fair incision of >8.0 mm.  Pupillary Aperture 4.0mm. Onpositioning holes in each haptic for suture to sclera fixation. (9-0 Prolene-spatula Needle)