CB144 UV2 PMMA IOL (Omni Lens)
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
Showing 57–84 of 207 results
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
Hydrophilic Acrylic for < 2.20mm incision Surgery, with Spherical Surface f, extended Range in myopia, from France and IOLART (GR/CY)
Hydrophilic Acrylic for < 2.20mm incision Surgery, with Aspherical posterior Surface (Aberration Neutral), from France and IOLART (GR/CY)
Based on the Crystalens Platform -Embedded Polymide haptics into the hinged Silicone Plate of the IOL. with Aspheric Optics. B+L will supply AO1UV (11,5mm) and AO2UV (12,0) for smaller/hyperopic and larger/myopic eyes respectively (From +17 0 to +27.0 in 0,25D steps!)
3-piece IOL with PVDF haptics and 13.0mm overall diameter with spheric (202) or Zeiss-Aspheric (602) Optics
Preloaded single Piece hydrophobic C-loop Implant with heparinized Surface without Asphericity like 611.
Spheric Plate, hydrophilic with “hydrophobic” surface IOL available in extended dioptic Range.
Standard monodical IOL with high Abbe number
Hydrophobic Glistening Free IOL for incisions >2,2mm (BLIS Injection system)
Hydrophobic Glistening Free IOL with a posterior Toric Surface, for incisions >2,2mm (BLIS Injection system)
one piece hydrophilic IOL with EDOF undisclosed Refractive Technology , 4 point fixation -4 closed loops-.
Toric Customized Model has according to diopter possibility to correct astigmatism up to 15D in 0,25D steps.
NB : An AAO Task Force consensus statement requires EDOF IOLs to be within one line of BCVA of monofocal IOLs; to have 0.5D more of defocus than a monofocal at 20/30 level (therefore, approximately 1.25D defocus), and 50% patients to be better than 20/30.
one piece hydrophilic IOL with EDOF undisclosed Refractive Technology , 4 point fixation -4 closed loops-.
“The innovative technology and unique optics of the EyeMax lens diverts images away from the damaged part of the eye and enhances them to the healthy parts, leading to a significant improvement of vision for patients. The shape of the Eyemax Lens redirects the same high quality image at every point of the retina, leaving the selection of the best alternative macula to the human brain.” -so called “Proprietary Hyper-Wavefront Modified Optics by Optical Physist P Artal. Concept by Dr B Qureshi.
The Lens is combined with high + Specs to produce magnification.
Refractive Target +3D : 10% Mag, +6D 20% mag (+10 to 30%)
To obtain IOL visit www.londoneyehospitalpharma.com
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
Hydrophilic monofocal one Piece IOL with aspheric Optics
4-point support Hydrophilic monofocal one Piece IOL with aspheric Optics 6/11 optic-overall length
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Toric Customized Hydrophylic one Piece IOL. Axis of IOL to implanted always at 0-180.
Toric Customized Hydrophylic Multifocal Lens (customized sphere/ astigmatism) 0,25D steps. 4 concentric refractive rings!
Hydrophilic monofocal one Piece IOL with aspheric Optics for in the bag/ sulcus and sclera fixation through sutures
Hydrophilic monofocal one Piece IOL with aspheric Optics 6/13 optic-overall length
one piece hydrophilic IOL where the Optical Element is connected to the Supporting Annulus through a Helix to theoretically allowe pivoting of the optic.
one piece hydrophilic IOL with Soleco’s 4 small diameter refractive central zone (trifocal) , designed for kids/ bag/ sulcus and sclera fixation.
one piece hydrophobic IOL with 4 point fixation -4 closed loops.
one piece hydrophobic IOL with 4 point fixation -4 closed loops -Preloaded .