alfa Iris Clip Lens (CareGroup)
Iris fixated IOL from India. From the Care Group.
Showing all 24 results
Iris fixated IOL from India. From the Care Group.
Iris fixated IOL designed for a spherical correction in cases of inefficient capsular Support.
In our opinion it is primarily a posterior Chamber Lens (A*=116.8) that may be enclavated in the Anterior Chamber if needed (A*=115,7) Note that the aphakic and less expensive Version is Biconvex (Only +2D to +9.0 are plano-Convex)
*Optical
Designed by Dr Masket as a possible solution to Dysphotopic Phenomena. Recommended to keep Iris in Miosis for first 72H to avoid iris capturing
The NuLens Dynacurve accommodative IOL (NuLens, Ltd., Herzliya Pituah, Israel) consists of: 1) polymethyl methacrylate (PMMA) haptics that are designed to be placed in the ciliary sulcus; 2) a PMMA anterior reference plane that provides distance vision correction; 3) a small chamber containing a solid silicone gel and 4) a posterior piston with an aperture in the center.
Such IOL prototypes, even with silicone gel of a relatively low refractive index (1.40), have been shown in a primate eye to deliver more than 40.00 D of accommodation using only 500 µm of vertical diaphragm displacement. No wonder the principle was evaluated clinically in AMD Patients, providing additional evidence regarding the Concept of possible extreme Accommodation. This Prototype of lens required a 9mm incision to be inserted in the sulcus/bag.
one piece PMMA lens (13.5 mm) with 6.0 mm Optic. Primary for in the Bag Fixation/ Open Sky Approach. Better Options Offered for Sulcus Fixation
one piece PMMA lens (12.0 mm) with 6.5 mm Optic. Primary for in the Bag Fixation/ Open Sky Approach. Better Options Offered for Sulcus Fixation
one piece hydrophobic Acrylic lens with C-loop Haptics, For capsular bag fixation.
one piece PMMA lens (13mm) with 6.0 mm Optic. Primary for in the Bag Fixation/ Open Sky Approach. Better Options Offered for Sulcus Fixation
one piece PMMA lens (13.0 mm) with 6.5 mm Optic. Primary for in the Bag Fixation/ Open Sky Approach. Better Options Offered for Sulcus Fixation
one piece PMMA lens (13.0 mm) with 7.0 mm Optic. Primary for in the Bag Fixation/ Open Sky Approach. Better Options Offered for Sulcus Fixation
one piece PMMA lens (14,2 mm) with 6.5 mm Optic. Modified C- “J” Loop design. Primary for in the Bag Fixation/ Open Sky Approach in Extreme Myopia. Up to -10.0D Better Options Offered for Sulcus Fixation
one piece PMMA lens (14,2 mm) with 6.5 mm Optic. C- Loop design. Primary for in the Bag Fixation/ Open Sky Approach in Extreme Myopia. Up to -10.0D Better Options Offered for Sulcus Fixation
one piece PMMA lens (12mm) with 5.5 mm Optic. Primary for in the Bag Fixation. Better Options Offered for Sulcus Fixation
one piece PMMA lens (13.0 mm) with 7.0 mm Optic. Primary for in the Bag Fixation/ Sulcus for Open Sky Approach.
one piece hydrophilic Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon needs dedication and proficiency performing PCCC -the “right” way
one piece hydrophilic Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon needs dedication and proficiency performing PCCC -the “right” way. This Version corrects Astigmatism up to +8,00D.
one piece hydrophilic Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon needs dedication and proficiency performing PCCC -the “right” way. This Model is for Short/ Pediatric Cases of Eyes <18mm and WTW <10mm.
one piece hydrophilic Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon needs dedication and proficiency performing PCCC -the “right” way. This Model is for cases requiring combined Cataract/ Vitrectomy Surgery in Eyes with Large Pupils
one piece hydrophilic Acrylic lens with large C-loop Haptics and large Optic 7.0mm, For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
one piece hydrophilic Acrylic lens with 4 closed loop haptics for bag fixation only. Overall Length 10,5mm-11.0mm. Optic Diameter 5,5mm to 6.5mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
one piece hydrophilic Acrylic lens with large C-loop Haptics and large Optic of 6.5mm, For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
one piece hydrophilic Acrylic lens with large C-loop Haptics, For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
one piece hydrophilic Acrylic lens with 4 closed loop haptics for bag fixation only. Overall Length 10,5mm-11.0mm. Optic Diameter 5,5mm to 6.5mm. MICS Incision. Recommended A Constant for sclera fixation 120.6