Axis Quadraloop Toric (Omni Lens)

one piece Hydrophilic acrylic with 4 haptic fixation and astigmatism control T3 (1,5 D -IOL Plane) to T9 (6.0D IOL Plane) -7 models

online Calculator www.omnitoric.in

Camellens FIL 622-1 T IOL (Soleko)

one piece hydrophilic  IOL designed for in the bag/ alternative fixation (Named after the two bumps on each haptic)

Toric model with Real Axis Technology (1-6 Dpt, Place IOL always 0-180, Astigmatism is custome-made with 1degree accuracy,

CB144 UV2 PMMA IOL (Omni Lens)

one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation

CB144 UV2 PMMA IOL (Omni Lens)

one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation

EVOLVE EDOF Customized Toric Hydrophilic (Soleko)

one piece hydrophilic  IOL with EDOF undisclosed Refractive  Technology , 4 point fixation -4 closed loops-.

Toric Customized Model has according to diopter possibility to correct astigmatism up to 15D in 0,25D steps.

NB : An AAO Task Force consensus statement requires EDOF IOLs to be within one line of BCVA of monofocal IOLs; to have 0.5D more of defocus than a monofocal at 20/30 level (therefore, approximately 1.25D defocus), and 50% patients to be better than 20/30.

Fluid Lens Accommodating IOL (PowerVision)

The FluidVision® Accommodating Intraocular Lens

Accommodation refers to the eye’s ability to dynamically adjust focus for clear vision at all distances. The FluidVision accommodating IOL from PowerVision contains a tiny amount of fluid inside the lens that moves in response to the natural muscle forces in the eye. The FluidVision lens provides True Accommodation™ by mimicking the eye’s natural accommodative process, changing shape and becoming thicker when the patient needs to see up close or thinner to see far away.  (from Powervision Website)

Unlike the Nulens and the Lumina this 3rd investigational Device meant to change the Curvature in vivo is meant to be placed in the capsule. 

Gemini Refractive Capsule (Omega Ophthalmics)

 

This Device is designed to protect the Crystalline Space for current and future applications. Replacing the 260mg cataract with our current  15mg implant technology might not be the right solution for the future. It may even survive the era of Refractive Indexing. (Possible applications with Augmented Reality/ Zooming and Drug delivery Reservoir.

 