Axis Quadraloop Toric (Omni Lens)
one piece Hydrophilic acrylic with 4 haptic fixation and astigmatism control T3 (1,5 D -IOL Plane) to T9 (6.0D IOL Plane) -7 models
online Calculator www.omnitoric.in
Showing 29–56 of 104 results
one piece Hydrophilic acrylic with 4 haptic fixation and astigmatism control T3 (1,5 D -IOL Plane) to T9 (6.0D IOL Plane) -7 models
online Calculator www.omnitoric.in
Online program to chose between 7 models controlling astigmatism from 1-4D (Spectacle Plane)
T3 (1,5 D -IOL Plane) to T9 (6.0D IOL Plane)
online Calculator www.omnitoric.in
one piece hydrophilic IOL designed for in the bag/ alternative fixation (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for in the bag/ alternative fixation (Named after the two bumps on each haptic)
Toric model with Real Axis Technology (1-6 Dpt, Place IOL always 0-180, Astigmatism is custome-made with 1degree accuracy,
one piece hydrophilic IOL designed for add on use- Concave Convex Optic (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic with bifocal optics (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic to correct Sphere/ Astigmatism / Presbyopia +3.0 Spectacle Plane (Named after the two bumps on each haptic)
one piece hydrophilic IOL designed for add on use- Concave Convex Optic to correct Sphere/ Astigmatism (Named after the two bumps on each haptic)
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
one piece PMMA 13/13.5 mm modified C Haptic, 2 positioning holes on the optic body. For Sulcus/ Iris and Sclera Fixation
one piece hydrophilic IOL with EDOF undisclosed Refractive Technology , 4 point fixation -4 closed loops-.
Toric Customized Model has according to diopter possibility to correct astigmatism up to 15D in 0,25D steps.
NB : An AAO Task Force consensus statement requires EDOF IOLs to be within one line of BCVA of monofocal IOLs; to have 0.5D more of defocus than a monofocal at 20/30 level (therefore, approximately 1.25D defocus), and 50% patients to be better than 20/30.
one piece hydrophilic IOL with EDOF undisclosed Refractive Technology , 4 point fixation -4 closed loops-.
Hydrophilic monofocal one Piece IOL with aspheric Optics
4-point support Hydrophilic monofocal one Piece IOL with aspheric Optics 6/11 optic-overall length
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Customized Refractive correction of sphere and astigmatism (0,25D steps) Ability to plan all lenses at same axis (usually 0-180)
Toric Customized Hydrophylic one Piece IOL. Axis of IOL to implanted always at 0-180.
Toric Customized Hydrophylic Multifocal Lens (customized sphere/ astigmatism) 0,25D steps. 4 concentric refractive rings!
Hydrophilic monofocal one Piece IOL with aspheric Optics for in the bag/ sulcus and sclera fixation through sutures
Hydrophilic monofocal one Piece IOL with aspheric Optics 6/13 optic-overall length
one piece hydrophilic IOL where the Optical Element is connected to the Supporting Annulus through a Helix to theoretically allowe pivoting of the optic.
one piece hydrophilic IOL with Soleco’s 4 small diameter refractive central zone (trifocal) , designed for kids/ bag/ sulcus and sclera fixation.
The FluidVision® Accommodating Intraocular Lens
Accommodation refers to the eye’s ability to dynamically adjust focus for clear vision at all distances. The FluidVision accommodating IOL from PowerVision contains a tiny amount of fluid inside the lens that moves in response to the natural muscle forces in the eye. The FluidVision lens provides True Accommodation™ by mimicking the eye’s natural accommodative process, changing shape and becoming thicker when the patient needs to see up close or thinner to see far away. (from Powervision Website)
Unlike the Nulens and the Lumina this 3rd investigational Device meant to change the Curvature in vivo is meant to be placed in the capsule.
This Device is designed to protect the Crystalline Space for current and future applications. Replacing the 260mg cataract with our current 15mg implant technology might not be the right solution for the future. It may even survive the era of Refractive Indexing. (Possible applications with Augmented Reality/ Zooming and Drug delivery Reservoir.
By ClarVistamedical -aquired by Alcon- comes a multicomponent IOL from Hydrophobic acrylic that the optic is adapted to the blue rim in situ. CE Marked.
one piece hydrophobic IOL with 4 point fixation -4 closed loops.
one piece hydrophobic IOL with 4 point fixation -4 closed loops -Preloaded .
one piece hydrophobic IOL with traditional design.