Normal range (+0.0 D to +4.0 D spectacle plane)
Showing all 17 results
ACRIOL TORIC MULTIFOCAL (ATM) -yellow tinted hydrophobic- IOL -(Care Group)
Hydrophobic yellow tinted with open modified C-loop haptic configuration, refractive/ diffractive IOL that corrects Astigmatism -1-4 dpt . (IOL plane) 360 Square edge Optics. 0,5 Increment step
AcrySof IQ PanOptix TFNT00 (Alcon)
one piece hydrophobic Acrylic IOL , trifocal refractive diffractive design, with +2.17D add and +3.25D add (IOL Plane)
AcrySof IQ PanOptix Toric TFNT (Alcon)
one piece hydrophobic Acrylic IOL , trifocal refractive diffractive design, with Astigmatism control 1.0D to 3.75D (IOL-Plane)
AS-6D iDIFF Plus -yellow tinted hydrophilic- IOL R Cloop or P Plate -(Care Group)
“iDIFF Plus is a newer generation refractive-diffractive presbyopic IOL with an increasing step height diffractive pattern combined with increased step angulation between transition zones, resulting in superior optical quality for both distance and near. The design enables balanced distribution of light (60/40 light distribution for far and near respectively) and higher MTF values, which increases contrast sensitivity in all lighting conditions and reduces the effects of scattered light, such as persistent glare and haloes and is pupil independent.” copied from website.
Comes as iDiff R (C-loop haptics) and iDiff P (plate) in 3 Adds +4.00/ +3.50/ +3.00
TECNIS Symfony EDOF Toric (ZXT)
EDOF IOL on TECNIS Platform , posterior achromatic diffractive surface designed to reduce chromatic aberrations for enhanced image contrast, “echelette: feature to extend the range of vision. Toric Correction from 1.50 to 3.75D (4 models) IOL Plane
Tek-Clear Accommodative IOL (TEKIA)
One piece Accommodative IOL Designed to fill the Capsule from Jose Vargas MD
Tek-Tor Model 820 / 820Y
One piece with 4-modified closed loop Haptics IOL from Hydrophilic Acrylic for Astigmatism Correction +1.50D/ +2.25D / +3.0D at IOL plane.
Trulign Toric IOL (model BL1UT)) Bausch+Lomb
Based on the Crystalens Platform -Embedded Polymide haptics into the hinged Silicone Plate of the IOL. B+L will supply AT50T (Spheric Toric Optics) or aspheric Optics (BL1UT) This Lens has better UV coverage then previous model (BL1AT)
Ultima Toric Multifocal UTM-1 -yellow tinted hydrophilic- Plate IOL (Care Group)
Yellow Hydrophilic Plate Aspheric Bifocal IOL for Astigmatism Control.
ZEISS AT LARA toric 929M/MP
Diffractive, bitoric aspheric (aberration Neutral) Hydrophilic Acrylic, Depth of Focus Extending by 0,95D and 1,90D. MP _ preloaded
ZEISS AT LISA toric 909M/MP
Bifocal, Diffractive, toric aspheric (aberration correcting) Hydrophilic Acrylic, Near Add at IOL plane +3.75D MP _ preloaded
ZEISS AT LISA tri (toric) 939MP preloaded
Trifocal, Diffractive, toric aspheric (aberration correcting) Hydrophilic Acrylic, Intermediate Add +1.66D , Near Add at IOL plane +3.33D – IOL Plane. Preloaded only
ZEISS AT TORBI 709M/MP
Preloaded plate bitoric Hydrophilic Implant with Spherical Aberration Contol. (SA neutral) MP _ preloaded



















