311 Aniridia Implant (Ophtec)
https://www.youtube.com/watch?time_continue=29&v=KJ-7u2QWqw4
IOL-Iris Composite device with 4mm optic. Requires a big wound, We do not advice utilizing anything but black!
Showing 1–28 of 44 results
https://www.youtube.com/watch?time_continue=29&v=KJ-7u2QWqw4
IOL-Iris Composite device with 4mm optic. Requires a big wound, We do not advice utilizing anything but black!
Iris fixated IOL from India. From the Care Group.
Requires huge incision of >10.0mm. Pupillary Aperture 3.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle
Requires huge incision of >10.0mm. Pupillary Aperture 5.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle. Also without Optic Available.
NB Intraop support of the IOL with Long Prolene Needle (Dr Sundmacher et al) https://www.youtube.com/watch?v=ucrk-EVDdMU
Requires huge incision of >10.0mm. Pupillary Aperture 3.0mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle Opening in the diaphragm inferiorly for the injection of Vitreous Fluid Substitutes/ inferior iridotomy for silicone oil.
Requires huge incision of >10.0mm. Pupillary Aperture 4.5 mm. For Sclera fixation through sutures. 9-0 Prolene/spatula needle
Iris fixated IOL designed for a spherical correction in cases of inefficient capsular Support.
In our opinion it is primarily a posterior Chamber Lens (A*=116.8) that may be enclavated in the Anterior Chamber if needed (A*=115,7) Note that the aphakic and less expensive Version is Biconvex (Only +2D to +9.0 are plano-Convex)
*Optical
PMMA Iris Fixated IOL for correction of Hyperopia.
NB: we no longer recommend the use of this lens in phakic eyes
Iris fixated PMMA IOL for myopia correction in Phakic Eyes. A preferred choice for most patients.
Iris fixated IOL designed for a spherical and cylindrical correction of myopic and hyperopic eyes.
N.B. The site does NOT recommend the use of this lens in Hyperopic Phakic Eyes.
One piece hydrophilic Acrylic plate lens with 4closed loop Haptics. Aspherical Optics and 6.0 mm optical Zone. For capsular bag fixation.
Based on the Crystalens Platform -Embedded Polymide haptics into the hinged Silicone Plate of the IOL. with Aspheric Optics. B+L will supply AO1UV (11,5mm) and AO2UV (12,0) for smaller/hyperopic and larger/myopic eyes respectively (From +17 0 to +27.0 in 0,25D steps!)
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
Hydrophilic acrylic aspheric IOL with central hole plus peripheral holes in 3 sizes , 12.00 mm,12.50 mm and 13.00 mm
Optic Size 4.65mm to 5.5mm according to dioptric correction
Range -3D to -23.0 D
EDOF adding +1,50D bisegmented design, one piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm. Femto Capsulorhexis “ready” IOL
One piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm.
Gallilean Type of Telescope: This Old-fashioned approach offers magnification through combination of a large + lens (up to +100D) placed in the bag and a strong meniscus minus AC Implant. Made from Lenspecial -Milano, Italy. (PMMA) System has an incredible 200D dioptic Range (+100D to -100D)
Gallilean Type of Telescope: This Old-fashioned approach offers magnification through combination of a large + lens (up to +100D) placed in the bag and a strong meniscus minus AC Implant. Made from Lenspecial -Milano, Italy. (PMMA)
Gallilean Type of Telescope: Combines a PMMA Rim with a double lens system. The PMMA Ring has 10.3mm diameter
One piece hydrophilic Acrylic lens with 4 open loop haptics with aspherical surface fror Capsular, sulcus and Sulcus-Sclera fixation. Enlarged Haptics for possible Suture Fixation
One piece hydrophilic Acrylic lens with 4 open loop haptics with aspherical surface fror Capsular, sulcus and Sulcus-Sclera fixation. Enlarged Haptics for possible Suture Fixation
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add that may be placed in the eye in cases of inadequate capsular support
One piece plate hydrophilic Acrylic lens with segmented Aspheric Optic offering +3.0 Add that may be placed in the eye in cases of inadequate capsular support. Individualized Sphere and Astigmatism correction (up to +12.0D)
Hydrophilic Acrylic for <2.00mm incision Surgery, with posterior Surface Aspheric SA-neutral, from France and IOLART (GR/CY)
One piece hydrophilic Acrylic plate lens, aspherical Optics and optical Zone from 5,5 to 7.0 according to dioptic correction required . For capsular bag fixation.
Requires fair incision of >7.0mm. Pupillary Aperture 3.5mm. Not for sclera fixation
larger then 67. 67A total Diameter 14.0mm. Intended for myopic eyes. Requires fair incision of >7.0mm. Pupillary Aperture 3.5mm. Not for sclera fixation