360 Square Edge

Showing 29–56 of 164 results

Camellens FIL 622-1 T IOL (Soleko)

one piece hydrophilic  IOL designed for in the bag/ alternative fixation (Named after the two bumps on each haptic)

Toric model with Real Axis Technology (1-6 Dpt, Place IOL always 0-180, Astigmatism is custome-made with 1degree accuracy,

CLARE (Cristalens)

Hydrophilic Acrylic for < 2.20mm incision Surgery, with  Spherical Surface  f, extended Range in myopia, from France and IOLART (GR/CY)

Clareon AutonoMe CNA0T0 -Alcon

one piece hydrophobic Acrylic monofocal IOL with aspheric optics, Preloaded with brilliant Single Use, C02 Propulsion System. Glistening Free.

CRISTAL (Cristalens)

Hydrophilic Acrylic for < 2.20mm incision Surgery, with  Aspherical posterior  Surface (Aberration Neutral), from France and IOLART (GR/CY)

CT ASPHINA 409M/MP

Preloaded plate Hydrophilic Implant with Spherical Aberration Contol. (Aspherisity Neutral)

CT ASPHINA 509M/MP

Preloaded plate Hydrophilic Implant with negative Spherical Aberration Contol. (SA negative) MP _ preloaded

CT LUCIA 211P

Preloaded single Piece hydrophobic C-loop Implant with heparinized Surface without Asphericity like 611.

CT LUCIA 611P

Preloaded single Piece hydrophobic C-loop Implant with heparinized Surface and Zeiss Unique Spheric (outer Area)/Aspheric (inner Area) profile. (ZO ZEISS Optic)

CT Spheris 204

Spheric Plate,  hydrophilic with “hydrophobic” surface IOL available in extended dioptic Range.

Diffractiva-aA/ aA Yellow HumanOptics

One piece  hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive/diffractive technology offering +3.50D Add (IOL Plane). For capsular bag fixation. DOLA Technology: Diffractive Optic Local Asphericity –DOLA– meant to reduce Halo/ Dysphotopic Burden of Bifocal IOLs.

EAZ-Y (Cristalens)

yellow tinted hydrophobic , posterior Surface Aspheric SA-neutral, Preloaded IOL from France and IOLART (GR/CY)

EDEN Swiss Advanced Vision

EDEN:  Proprietary EDOF technology that excibits a unique exagerrated aspheric (central region 1mm- Instant Focus Technology), combined with a diffractive Zone (3.5mm) and Refractive (to 6mm) properties.  One piece Hydrophilic acrylic with double closed loops IOL in two Sizes.

EVOLVE EDOF Customized Toric Hydrophilic (Soleko)

one piece hydrophilic  IOL with EDOF undisclosed Refractive  Technology , 4 point fixation -4 closed loops-.

Toric Customized Model has according to diopter possibility to correct astigmatism up to 15D in 0,25D steps.

NB : An AAO Task Force consensus statement requires EDOF IOLs to be within one line of BCVA of monofocal IOLs; to have 0.5D more of defocus than a monofocal at 20/30 level (therefore, approximately 1.25D defocus), and 50% patients to be better than 20/30.

Femtis Comfort FB-313 MF15 -Oculentis

EDOF adding +1,50D bisegmented design, one piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm. Femto Capsulorhexis “ready” IOL

Femtis FB-313 -Oculentis

One piece plate hydrophilic Acrylic lens with Aspheric Optic offering posibility of anterior Capsulorhexis Fixation between 4.8 and 5,5 mm.