TORICA-aA/ aA Yellow HumanOptics
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive technology. For capsular bag fixation. Infinite Spherical/ Astigmatism Correctiuon -20D to +40D and astigmatism +1D to +20D
Showing 197–222 of 222 results
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive technology. For capsular bag fixation. Infinite Spherical/ Astigmatism Correctiuon -20D to +40D and astigmatism +1D to +20D
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive/diffractive technology offering +3.50D Add (IOL Plane). For capsular bag fixation. DOLA Technology: Diffractive Optic Local Asphericity –DOLA– meant to reduce Halo/ Dysphotopic Burden of Bifocal IOLs. Astigmatism Correctiuon +1D to +6.0 D IOL Plane.
one piece hydrophilic Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon needs dedication and proficiency performing PCCC -the “right” way
one piece hydrophilic Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon needs dedication and proficiency performing PCCC -the “right” way. This Version corrects Astigmatism up to +8,00D.
one piece hydrophilic Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon needs dedication and proficiency performing PCCC -the “right” way. This Model is for Short/ Pediatric Cases of Eyes <18mm and WTW <10mm.
one piece hydrophilic Acrylic lens for “Bag in the Lens” Placement. The BIL conceived patented and promoted by Dr Tassignon needs dedication and proficiency performing PCCC -the “right” way. This Model is for cases requiring combined Cataract/ Vitrectomy Surgery in Eyes with Large Pupils
one piece Hydrophilic Acrylic lens (15.0 mm) with 6.5mm Optic. With Positioning holes for sclera fixation (9-0 Prolene CTC-6L Ultima SPATULA)
one piece hydrophilic Acrylic lens with large C-loop Haptics and large Optic 7.0mm, For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
one piece hydrophilic Acrylic lens with 4 closed loop haptics for bag fixation only. Overall Length 10,5mm-11.0mm. Optic Diameter 5,5mm to 6.5mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
one piece hydrophilic Acrylic lens with large C-loop Haptics and large Optic of 6.5mm, For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
one piece hydrophilic Acrylic lens with large C-loop Haptics, For capsular bag/ sulcus fixation. Overall Length 15.0mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
one piece hydrophilic Acrylic lens with 4 closed loop haptics for bag fixation only. Overall Length 10,5mm-11.0mm. Optic Diameter 5,5mm to 6.5mm. MICS Incision. Recommended A Constant for sclera fixation 120.6
Hydrophilic Add On Monofocal IOL from 11.00 to +14.00mm with 6,2mm Optic Diameter. Vault Height 0.00mm.
Hydrophilic Add On Trifocal IOL from 11.00 to +14.00mm with 6,2mm Optic Diameter. Vault Height 0.00mm. Adds +1.8D intermediate and +3.5D for near.
Hydrophilic Add On Trifocal IOL from 11.00 to +14.00mm with 6,2mm Optic Diameter. Vault Height 0.00mm. Adds +1.8D intermediate and +3.5D for near. This model can correct astigmatism from +0,5 D to +10.0 D.
Hydrophilic Add On Monofocal IOL from 11.00 to +14.00mm with 6,2mm Optic Diameter. Vault Height 0.00mm. This model also corrects astigmatsim from 0.5D to 10.0D (o,5D increments)
Hydrophilic -Biconvex plate with 4 haptic closed loop fixation vs closed modified C-loop configuration. one Piece IOLs from Care Group This model with aspheric 360 Square edge Optics.
Yellow Hydrophilic Plate Aspheric IOL for Astigmatism Control. Wide Range. Above 10D of astigmatism the lens is Custom-ordered
Yellow Hydrophilic Plate Aspheric Bifocal IOL for Astigmatism Control.
one piece Aspheric Hydrophilic with Blue Blocker
Diffractive, bitoric aspheric (aberration Neutral) Hydrophilic Acrylic, Depth of Focus Extending by 0,95D and 1,90D. MP _ preloaded
Diffractive, aspheric (aberration correcting) Hydrophilic Acrylic, Depth of Focus Extending by 0,95D and 1,90D. MP _ preloaded (BLUEMIXS 180)
Bifocal, Diffractive, aspheric (aberration correcting) Hydrophilic Acrylic, Near Add at IOL plane +3.75D MP _ preloaded
Bifocal, Diffractive, toric aspheric (aberration correcting) Hydrophilic Acrylic, Near Add at IOL plane +3.75D MP _ preloaded
Trifocal, Diffractive, toric aspheric (aberration correcting) Hydrophilic Acrylic, Intermediate Add +1.66D , Near Add at IOL plane +3.33D – IOL Plane. Preloaded only
Preloaded plate bitoric Hydrophilic Implant with Spherical Aberration Contol. (SA neutral) MP _ preloaded