not available
Showing 57–76 of 76 results
Superflex Aspheric 920H (Rayner)
Anterior Aspheric SA=0 with larger then the C-flex Optical (Body) Size -6.255mm
Superflex Monofocal 620H (Rayner)
Anterior Aspheric SA=0 with larger then the C-flex Optical (Body) Size -6.255mm
Tek-Lens II Model 812/ 812Y (TEKIA)
One piece hydrophilic Acrylic lens with modified C loop Haptics and aspheric Optics Available also in Yellow Tint (812Y) Extended Dioptic Range to Hyperopia (+42D) and large Optic (6,5mm)
Tek-Lens II Model 820/ 820Y (TEKIA)
One piece hydrophilic Acrylic lens with four modified closed loop Haptics and aspheric Optics Available also in Yellow Tint (820Y) Extended Dioptic Range to Hyperopia (+42D)
Tek-Lens II Model 830/ 830Y (TEKIA)
One piece hydrophilic Acrylic lens with four modified closed loop Haptics and aspheric Optics Available also in Yellow Tint (830Y) Extended Dioptic Range to Hyperopia (+42D)
Tek-Tor Model 820 / 820Y
One piece with 4-modified closed loop Haptics IOL from Hydrophilic Acrylic for Astigmatism Correction +1.50D/ +2.25D / +3.0D at IOL plane.
TORICA-aA/ aA Yellow HumanOptics
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive technology. For capsular bag fixation. Infinite Spherical/ Astigmatism Correctiuon -20D to +40D and astigmatism +1D to +20D
TORICADIFF-aA/ aA Yellow HumanOptics
One piece hydrophilic Acrylic lens with C-loop Haptics, aspherical Optics and refractive/diffractive technology offering +3.50D Add (IOL Plane). For capsular bag fixation. DOLA Technology: Diffractive Optic Local Asphericity –DOLA– meant to reduce Halo/ Dysphotopic Burden of Bifocal IOLs. Astigmatism Correctiuon +1D to +6.0 D IOL Plane.
type 63A Morcher Hydrophobic Monofocal
one piece hydrophobic Acrylic lens with C-loop Haptics, For capsular bag fixation.
type 63A Morcher Preloaded Hydrophobic Monofocal
one piece hydrophobic Acrylic lens with C-loop Haptics, For capsular bag fixation. Preloaded
Vivinex MultiSert XC1-SP, XY1-SP
preloaded Hydrophobic Acrylic (Vivinex) with Aspheric Design with UV -filter (XC1-SP) and Blue Light Filtration (XY1-SP)
WIOL-CF /MEDICEM
Wichterle (Continouos Focus) IOL is an innovative IOL without Haptics made from a 8.9mm Bioanalogic Hydrogel with a number of proprietary characteristcs like negative spherical aberrations providing by its smooth hyperbolic curve, an infinite number of focal points that extend the depth of focus, The Refractive power is maximal in the center and continuously decreases without steps to the periphery,
YSQ FL600ASP GenNext Aspheric Foldable -natural yellow- (Omni Lens)
one piece Aspheric Hydrophilic with Blue Blocker
















