ALCON/NOVARTIS

Showing all 24 results

AcrySof IQ ReSTOR SND1TT/ SV25TT (Alcon)

one piece hydrophobic -yellow-Acrylic IOL , bifocal refractive diffractive apodized design with +3.0 D (SN6AD1TT) and +2.5 D (SV25TT) / This toric Model with astigmatism compensation from 1D to 3.75D in IOL Plane.

AcrySof IQ Toric SN6ATT

one piece hydrophobic Acrylic monofocal IOL with aspheric optics and Astigmatism cotrol from 1D to 6D (IOL Plane)

AcrySof MA60 MA/ MN60 MA

White (MA) or Yellow spherical Optic, 3-piece IOL for LOW POWERS (-5.0D to +5.0D)only.  Also for Alternative Fixation Sulcus/Sclera/ Iris

AcrySof SA60 AT/ SN60 AT

White (MA) or Yellow spherical (SN) with aspheric Optic One piece Hydrophobic IOL, extended dioptric Range to +40.0 D.

BSS plus (Alcon)

BSS Plus is comprised from TWO solutions,

BSS 1 – 480ml- of physiologic solution in which

BSS 2 -20ml is added to provide additional dextrose and Gluthathione for better Endothelial protection .

Centurion Vision System (Alcon)

Centurion was launched by Alcon in 2013.  Since then it has easilty become the no 1 cataract emulsifier in the US.

Benefits:

1/Active Fluidics: employs “Pressurized” Fluidics thus Surgeon can set and maintain (as well as incisions are well constructed!)  target IOP throughout the procedure. Vs Gravitational Fluidics where the pressure is fixed. or there is a lag while elevating the pole of the BSS…. Eliminates the need to manually adjust the Fluid Pressure.

2/ INTREPID  Micro Coaxial System: This unique “bend” but “Balanced” Tip is cuppled with the unique 0.9mm Nanosleeve (at the Ozil IP Handpiece) featured in the latest Infinity. This tip is -of course-a must when using the machine since it reduces tip movement and leak at incision and greatly enhances tortional power.

3/ excellent interface of parameter adjustment to regulate flow and Efficiency at the Tip, if however the user is accustomed to the latest generation of Pulse/ Burst and Hyperpulse balance of the Infinity along with the new feature: the bimodal set of Vacuum and Asp Flow. Otherwise you can be intimidated if you try to take your first ride on the Centurion (which can be very disapointing!)

Clareon AutonoMe CNA0T0 -Alcon

one piece hydrophobic Acrylic monofocal IOL with aspheric optics, Preloaded with brilliant Single Use, C02 Propulsion System. Glistening Free.

Constellation Vision System (Alcon)

NB

Even if marketed only as a posterior Segment unit, the Constellation with the Venturi pump and pressurized fluidics combined with Alcon’s superb newer Phaco handpiece with the nanosleeve, offers an excellent Phacoemulsifier at least as good if not better then the all time honored Infinity System.

DisCoVisc OVD/ Alcon

1.65% NaHA with 4% Chondroitin Sulfate, 1.65 Million Daltons Molecular Weight and medium/low Viscosity 75.000 cPs Zero shear rate, in 1.0ml syringe. 27G cannula. Classified by ALCON as Viscous Dispersive

DuoVisc OVD/ Alcon

Viscoat: Medium Viscosity Dispersive (Viscosity Zero Shear stress 40.000cps), 3% NaHA-4% Chondroitin Sulfate

ProVisc: Viscous Cohesive,  1% NaHA, 2.4million Dalton and Dynamic Viscosity 39.000 cps. Use during Capsulorhexis and IOL placement,

 

iLux (Tear Film Innovations-Alcon)

this Device is a hand held portable device to heat ans sophistically squize the eyelid and treat MGD/ Evaporative Dry Eye Syndrome. (Aquired by Alcon in 2018)

Infiniti Vision System (with Ozil + IP -Alcon)

Latest (and literally last) upgrade entails Ozil Torsional Handpiece, Interpid PLUS Fluidics Management System (FMS) to decrease postocclusion Surge and maintain chamber stability. Moreover it allows frank generation of Vacuum up to 600.

the Intelligent Phaco (iP) Module: software to increase followability, minimize post-occlusion Surge and phaco Efficiency by keeping the lens material at the shearing plane.

1/ Pulse and Hyperpulse Modes (Ozil Pulse) 

Adjust Phaco Power + Torsional Amplitude separately as well as pulse per second  (PPS) / % Time On and Linear or not application of energy.

2/ Smart Pulse (NeoSoniX Pulse) 

Complements traditional micropulse phaco settings below 20msec by allowing extra low energy delivery.

3/ Linear Burst 

Idea is to allow better occlusion by separetely controlling Burst Delivery/ Energy and Duty Cycle

 

 

LenSx Laser System-Femtosecond Laser- (Alcon)

Newest Gen LenSx® Laser features a high-definition OCT (Fourier Domain FD-OCT) achieving 8,5mm visability and an innovative patient interface (SoftFit-2012  -fixates the eye to a soft contact lens insert, minimizing cornea compression) and fast treating time. According to the manufacturer now the typical total treatment times are under two minutes.

Online Alcon ToricOL Calculator (Barrett/ Holladay I Formula)

The Alcon Online Toric IOL Calculator will choose appropriate Toric Lens in IQ, SA6A, ReSTOR +2.5 or +3.0 and PanOptix Toric but inserting the IOL Spherical Equivalent Power (usually from the IOLMaster) and Surgically induced Astigmatism which is NOT calculated for you anymore. (The Software redirects you to the Hill Site (www.sia-calculator.com) which needs from the user to register (free of charge)

https://www.myalcon-toriccalc.com/#/countryLanguage

ORA intrasurgical Aberrometry (Alcon)

real time measurments and intra surgical recommendation….as long as Cornea is not over hydrated/ beaten up and the eye is pressurized. ELP in aphakia is still assumed..

 

PMMA Alcon Lenses -Anterior Chamber- All 6 Sizes

All the Available PMMA Models from Alcon for Use in the Anterior Chamber. All require large incisions (5.7mm). MUST Follow Sizing Guidance ! 6 Models Available ….

For detailed description visit the site

https://www.myalconstore.com/education-resources/surgical-product-information/